Send Diagnostic - IBM Ultrastar 36LZX Specifications

3.5 inch scsi hard disk drive
Hide thumbs Also See for Ultrastar 36LZX:
Table of Contents

Advertisement

Ÿ The second part is executed after the spindle motor is started. This includes disk access (seek), R/W
channel, and error correction circuitry verification. A reserved area on the disk is used for this test.
Both tests are performed as a result of the SEND DIAGNOSTIC command. The SEND DIAGNOSTICS
will fail with CHECK CONDITION status if it is issued while the spindle motor is not turning. (Such as
after STOP command has been received.)
Note: The self diagnostic is also performed at Power On Reset time.
Note: The SCSI bus signals will not be corrupted when the device is executing the SEND DIAGNOSTIC
command.
8.34.1 Send Diagnostic Page 0
This page requests that the drive return a list of supported pages on the next receive diagnostics com-
mand.
Byte
7
0
Page Code = 0
1
Reserved = 0
2 - 3
Page Length = 0
Figure 148. Diagnostic Page 0
8.34.2 Send Diagnostic Page 40
This allows the initiator to translate a logical block address or physical sector address to the other format.
The address to be translated is passed to the target with the Send Diagnostic command and the results
are returned to the initiator by the Receive Diagnostics command.
The target will read the parameter list from the initiator and, if no errors are detected in the parameter
list, Good Status will be returned. The data translation will be performed upon receipt of the Receive
Diagnostics command.
Byte
7
6
0
Page Code = 40h
1
Reserved = 0
2-3
Page Length = 0Ah
4
Reserved = 0
5
Reserved = 0
6-13
Address to Translate
Figure 149. Diagnostic Page 40
Supplied Format may take one of the following three values:
Bit
6
5
4
3
Bit
5
4
3
Ultrastar 36LZX hard disk drive specifications
2
1
0
2
1
0
Supplied format
Translate format
171