7.8.4 Non-operating shock
The drive withstands the following square shock pulse with no permanent damage:
Ÿ Accelerating level of 50 G
Ÿ Duration time of 11 ms
Ÿ Rise and fall time of 1 ms
Ÿ Minimum velocity change of 4.23ms
The drive withstands the following half-sine shock pulse:
Ÿ No data loss with 75G, 11ms
Ÿ No data loss with 225G, 2ms
The shocks are applied in each direction of the drive for three mutually perpendicular axes and one axis
at a time. Input levels are measured on a base plate where the drive is attached with four screws.
The drive withstands the following Rotational Shock:
Ÿ No data loss with Rotational Shock 30000rad/s
NOTE: Actuator is automatically locked at power-off to keep the heads on a landing zone.
Ultrastar 36LZX hard disk drive specifications
2
, 1ms applied around the axis of actuator pivot.
51