5-2 Measurement of Average Value Indication (Temporary Memory)

1. A long press (approx. 1 sec.) of a Hold・Average Key ② performs temporary
Memory Measurement to display Average Value Indications.
( A max. measurement point capable for Temporary Memory is 20)
2. This Temporary Memory can be deleted when Power is OFF
(and Auto-Power OFF is as well)
3. Average Value Measurement is performed in a measurement of Hold Mode.
Measured data memory is capable of memorizing temporarily「AVE1」,
「AVE2」,・・・・ and 「AVE 20」at the Maximum.
4. A press of the Hold・Average ② key during in process of the measurement
turns to Average Value mode and on LCD ⑦「AVE_ _」is indicated and
shows the average value measured up to the points.
Then by operating numerical value setting keys「▲」,「▼」④, measured
values can be recalled and confirmed.
On the place of〔AVE〕on display, recalled measured numbers (1 to 20) are
indicated and each measured value can also be confirmed respectively.
And then〔HOLD〕or〔AVE〕is not indicated.
* During this mode, Auto Power OFF can not be operated.
* An Average Value Mode can not return to a measuring operation.
When returning, refer again to 7. below and try to set again.
5. When reading erroneous data during a measurement of Average Value Indications, a long press and hold
(1 sec.) of a Numerical Value Setting Key 「▼」 ④ is capable of deleting the only last data stored
(*Only possible to operate the latest measured data.)
6. When measured numbers has reached 20 items, it automatically turns to
Average Value Indication mode in a second (the data at the 20
deleted by operating any keys)
Release the mode to return to a measuring operation.
7. A long press and hold (approx. 2 sec.) of the Hold・Average key ② make it
possible to release the mode.
Power SW key ① and Hold・Average key ② can only be used during a measurement in process of
Average Value Indication.
During a measurement of Average Value Indication, a setting function of Upper Limit Values turns ineffective.
When actuating Average Value Indication measurement during a use of a setting function of Upper Limit
Value, the setting function of an Upper Limit Value turn ineffective.
But, even in this case Upper Limit Value is being in process of storing unless Power is switched OFF, and it
returns to the Upper Value setting when a measurement of Average Value Indications has finished.