SANKO PM-101 Operating Instruction

Electric mortar, plaster moisture meter

Advertisement

Mortar・Plaster moisture meter
PM−101
- Electric moisture meter -
Operating Instruction MANUALS
CAUTIONS:
●Before using the Meter, read this INSTRUCTION MANUAL thoroughly and use
the Meter correctly.
●Keep this INSTRUCTION MANUAL with care and refer to it when necessary.
●In the event of any discrepancies, the original INSTRUCTION MANUAL
in Japanese is to be of final authority.
SANKO ELECTRONIC LABORATORY CO., LTD.
(株式会社 サンコウ電子研究所)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PM-101 and is the answer not in the manual?

Questions and answers

Summary of Contents for SANKO PM-101

  • Page 1 Meter correctly. ●Keep this INSTRUCTION MANUAL with care and refer to it when necessary. ●In the event of any discrepancies, the original INSTRUCTION MANUAL in Japanese is to be of final authority. SANKO ELECTRONIC LABORATORY CO., LTD. (株式会社 サンコウ電子研究所)...
  • Page 2: Table Of Contents

    Please ensure that this packaging is disposed of in an environmentally sensitive manner, which may be instructed by your Local Environmental Authority. To maximize the benefits of your new Mortar・Plaster Moisture Meter PM-101 please take some time to read these operating instructions.
  • Page 3: Characteristics ・Applications

    (MC-4) moisture contents of textiles, Foods, Chemical synthesis, Ceramic, etc. which once considered difficult to measure. 2. Specifications Model AQUA SEARCH SERIES PM-101 Method DC electric resistance type Mass moisture% Range 1.0 to 15.0 % 1 to 100 (MC mode) Resolution 0.1%, 1 (MC mode)
  • Page 4: Names

    3. Names 3-1 Main body Probe connector receptacle Probe connector ① Power SW (POWER) Switch ON or OFF. Switch ON after a probe has been hooked up to a main body. A display turns automatically to Error [E01] and Power-OFF because of Self Analysis Function when any abnormality is detected in the inner circuitry of a body.
  • Page 5: Probe

    ⑤ Lock key (LOCK) A press of a Lock key locks all the keys except POWER SW ① which prevents erroneous operations. Switch OFF to release the lock. ⑥ Upper Limit Value Key (H) Switch on Upper Limit Value Mode. Set to an optional numerical value with a numerical value setting key ④.
  • Page 6: How To Use

    Probe connector receptacle 4. How to use 4-1 Connection or disconnection of probe (ensure that Power Source of a main body is OFF). ・ Hook up the Probe connector ⑪ to a main body to meet the Arrow Mark of the Probe Connector ⑪ with the Mark of Probe connector Probe Connector Receptacle ⑧...
  • Page 7: How To Operate Probe

    4-4 How to operate Probe ・ Press the tip of the rubber against a measurement object evenly, squarely and with even power. ・ Make sure that the rubber electrode never be deformed or broken. ・ In case of measuring rough faces of a measurement object, choose a level face for the measurement or compensate or average a measurement value.
  • Page 8: Setting Of Upper Limit Values

    4-6 Setting of Upper Limit Values ・Press the Upper Limit Value Key「H」⑥ when Power ON is in process. ・A buzzer emits「peep」sounds and the「H」,「●」marks of an upper limit value indications and「15.0%」of the range of the upper limit are displayed. ・Press and hold a「▼」key ④ until it has reached to a desired upper limit value. Keeping the「▼」key ④...
  • Page 9: Measurements

    5. Measurements 5-1 Real time measurement 1. Turn on Power SW ① and confirm an indication of LCD. Display of measuring mode of 「M」Mortar・Concrete and 「LLL」 Turning on Power while pressing the probe to the object indicates 「LLL」 once on the display and then displays a measuring value in 2 to 3 seconds.
  • Page 10: Measurement Of Average Value Indication (Temporary Memory)

    5-2 Measurement of Average Value Indication (Temporary Memory) 1. A long press (approx. 1 sec.) of a Hold・Average Key ② performs temporary Memory Measurement to display Average Value Indications. ( A max. measurement point capable for Temporary Memory is 20) 2.
  • Page 11: Measurement Of Mc Mode

    6. Measurement of MC (Moisture Content) mode Select Moisture Content Mode by pressing a Mode Change key ③ after turning Power to ON. This MC mode is capable of using broad objects relating to Resistance. Changes of electric resistance depending on dryness and moisture indicates numerical values 「1 to 100」(No Unit).
  • Page 12: Dry Batteries

    9. Dry batteries 9-1 Indication of Voltage-drop Batteries run short when a battery mark indicating the state of charge of the batteries turns to 1 on the left lower side of LCD ⑦. By sliding open the lid of the battery case ⑩ placed on the backside of a main body, replace all the old batteries with new ones (watch battery life).
  • Page 13: Others

    11. Others 11-1 How to use moisture reading checker (option) Touch the electrode to the checker illustrated below when Power is ON. It is a good condition if indicated values are as per listed on the checker. If indicated values deviate, contact a store or our sales office to get it corrected. (subject to pay) *...
  • Page 14 Sales of Coating thickness meter, Pinhole detector, Condensator, Viscosity cup, Moisture meter, Needle detector, Iron piece detector Manufacturer: Sanko Electronic Laboratory Co., Ltd. Tokyo branch:Shibata Bldg., 2-6-4, Uchikanda, Chiyoda-ku, Tokyo 101-0047, Japan Tel 81-3-3254-5031 Fax 81-3-3254-5038 Osaka branch:Konishi Bldg., 2-3, Sugawara-cho, Kita-ku, Osaka 530-0046, Japan Tel 81-6-6362-7805 Fax 81-6-6365-7381 Nagoya branch:Meihoku Bldg., 3-11-27, Kinjo, Kita-ku, Nagoya 462-0847, Japan...