SANKO Coating Thickness Meter
SWT-7200Ⅱ
Instruction Manual
CAUTIONS:
Before using the Meter, read this INSTRUCTION MANUAL
thoroughly and use the Meter correctly.
Keep this INSTRUCTION MANUAL carefully and refer to this
when necessary.
In the event of any doubt arising, the original
INSTRUCTION MANUAL (Japanese) is to be final authority.
SANKO ELECTRONIC LABORATORY CO., LTD.
Tokyo・ Osaka・ Nagoya・ Fukuoka・ Kawasaki

Advertisement

loading
Need help?

Need help?

Do you have a question about the SWT-7200 II and is the answer not in the manual?

Questions and answers

Summary of Contents for SANKO SWT-7200 II

  • Page 1 Meter correctly. Keep this INSTRUCTION MANUAL carefully and refer to this when necessary. In the event of any doubt arising, the original INSTRUCTION MANUAL (Japanese) is to be final authority. SANKO ELECTRONIC LABORATORY CO., LTD. Tokyo・ Osaka・ Nagoya・ Fukuoka・ Kawasaki...
  • Page 2: Table Of Contents

    Contents Pages Attention for safety ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 1 Notes ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 4 Get started ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 5 ・ Contents in a package ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 5 ・ Names of part ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 6 ・ Items indicated on LCD ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 8 ・ How to fit batteries ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 9...
  • Page 3 Contents Pages Measurements with high/low limit setting ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 38 (1)Within limit values ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 38 (2)Over high limit ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 38 (3) Under low limit ・・・ ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 38 To store data ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 39 (1)Select a data storing palce ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 40 (2) Keep data from being stored ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・...
  • Page 4 Contents Pages Note to improve measuring accuracy ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 86 Trouble shooting ・・・・・・・・・・・・・・・・ ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 87 Specification * Main body ・・・・・・・・・・・・・ ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 90 * Probe (option) ・・・・・・・・・・・・・・・・・・・・・・・・・ ・・・・・・・・・・・・・・・・・・・・・・・・ 91 References (measurement proinciples) ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 92...
  • Page 5: Attention For Safety

    Attention for safety (to use in correct ways) To prevent you and your properties from damaging please take some time to read thoroughly this “Attention for Safety” and correct uses keep these instructions attentive to read when necessary. Warning ● Do not dump nor wet the gauge unit in water, otherwise it may cause damages. Please contact our distributor or sales office should submerged water into the unit.
  • Page 6 Attention For Safety (to use safely and correctly) Warning ! ● Never fail to remove batteries from the unit when not in use for a long time. Leakages occurred from deterioration of batteries may cause erroneous reactions or damages. Must !...
  • Page 7 Attention For Safety (to use safely and correctly) Attention ● Do not use Benzene or Thinner for cleaning and spray pesticides on the meter, otherwise it may cause cracks or malfunctions. Prohibition ● Do not store the meter in places getting high in temperatures such as in a car in strong sunlight or near heaters, otherwise it will be hazardous to the meter and may cause malfunctions.
  • Page 8: Notes

    Notes: ● Please read this manual thoroughly for correct operations before getting started. ● This meter is a precision gauge. Please handle with care. ● Do not tug, bend, fold or curl up forcefully the cables of probes. ● Do not knock or scratch objects with the tip of a probe. ●...
  • Page 9: Get Started

    Get started ◆ Contents in a package Check the package if there are the following items inside it. ・ Main unit SWT-7200Ⅱ ・ Dry batteries R6P/AA (2 pieces) ・ Carrying case ・ Instruction manual (this manual) ・ Warranty/User resistor sheet (Available only in Japan) ・...
  • Page 10: Names Of Part

    ◆ Names of part Probe socket Display Hand strap Keys Battery compartment (the back) Socket for AC adaptor connector Socket for USB connector ● Probe socket Connect an optional-exclusive SWT probe to the probe socket. (1) To measure a film thickness of coated, plated, lining layer on substrates made of ferrous material please use a probe of (Fe) series for the connection.
  • Page 11 (4) 「Cal No.」key A key to select calibration in a high function al operation. (5) 「H/L」 key A key to set Upper/lower limits of measuring values in a high functonal operation. (6) 「STATIS-TICS」 key A key to process data with statistics stored in memory in a high functional operation. (7)...
  • Page 12: Items Indicated On Lcd

    Items indicated on LCD ● ① ② 「ZERO cal.」 or “Fe” 「Cal. w. foils」 “NFe” ③ ④ Reading of numerical values ⑤ μm “Low battery” indicator Transmit”Indicator ⑥ “Cal. No.” indicator ⑦ “High, lLow limit” indicator “Memory, mode, status” indicator ⑧...
  • Page 13: How To Fit Batteries

    ◆ How to fit batteries ① Open the battery lid on the back of the unit. Press down and slide the lid in direction of arrow to open. ② Insert batteries. Ensure correct battery polarity ○ 、 ○ for placement. +...
  • Page 14 ◆ How to connect or disconnect a probe ◎ Connect an optional, exclusive SWT probe to the main unit Select one of the probes suited for your application. Insert a probe connector into the probe socket of the main unit. Make sure of aligning the keyway leading to a smooth joint without doing by force.
  • Page 15: How To Hold Probe

    ◆ How to hold probes Cable Pinch and hold this part using fingers Black resinous ring Tip to press against a measurement object ◆ How to press a probe to an object ・ Keep the probe 5 cm or over away off metallic objects when not in use of measuring. ・...
  • Page 16: How To Operate

    How to operate (1) How to switch Power source Press ON/OFF key. START UP This message lasts for about 5 seconds. Caution PHASE Hold the probe in air without operation when Hold poobe the reading is on display. Or it may indicate in...
  • Page 17: 2)How To Switch Off

    (2) How to switch off Press ON/OFF key. The buzzer beeps, beeps. (twice) POWER The message lasts for about 5 seconds. OFF Terminating phase This unit switches off. -13-...
  • Page 18 3) How to select 「Calibration No: 」 It is capable of getting started on measurements immediately after by switching Power to ON as described on page10, 「it becomes possible to take measurements and adjusting」. However, it may make errors depending on material formation and shapes to be measured. To minimize measurement errors and obtain as accurate results as possible please be sure of carrying out 2 points adjustments of 「Zeroing」...
  • Page 19 (Fe) Your selected number flashes. - Caution μm The number flashes for about20 seconds. Press CAL No. key during the period of 20 Cal.No. Seconds, otherwise the buzzer beeps, beeps to return automatically to the beginning. (in this case, 「7」is canceled to return automatically to 「1」) .
  • Page 20 (3) Zeroing It is capable of getting started on measurements immediately after the message of 「START UP PHASE」 has disappeared as described on page 12. However, it may make errors depending on material formation and shapes to be measured. To minimize measurement errors and obtain as accurate results as possible please be sure of carrying out 2 points of adjustments of 「Zeroing」...
  • Page 21 Press ZERO key in case of pressing less than 10 times. The buzzer beeps. It stopes its DELETION function of LOCK/DELETE key and returns to the “LOCK” function. (Fe) The reading shows that 「Zeroing」 has completed and it becomes possible to take measuring and adjusting -...
  • Page 22 (4)Zeroing in special cases (Multi-layers) Measuring the thickness of the 4 layer (4 layer) by zeroing at the 3 layer. (3 layer) (2 layer) (1 layer) Coating films Substrate material In case of being painted as shown with multi-layers on the substrate there may be needs to measure thicknesses of each layer.
  • Page 23 OFFSET. Press ZERO key twice while this message is indicated on the screen (about 20 seconds). To continue. press ZERO twice. Caution This message is indicated on display for about 20 seconds. If no ZERO key is pressed when the reading is on screen, 「Zeroing」 is automatically interrupted and returns to the Press ZERO key .
  • Page 24 Press ZERO key in case of pressing the plate less than 10 times. The buzzer beeps. It stopes the LOCK function of LOCK/DELETE key and returns to the “LOCK” function. (Fe) 「Zeroing」 has completed and it becomes possible to - take measuring and adjusting operations of this unit.
  • Page 25 6)Calibration standard (CAL) ● Prepare 「Zero Plate」 used in 「Zeroing」. ● Prepare 「Thickness Standard」 which thicknesses is thicker or as thick as a measuring film. ● Place 「Thickness Standard」 on 「Zero Plate」. ● Press △ key or ▽ key. ▲ The buzzer emits a beeping sound.
  • Page 26 Caution This message「Calibration Standard」 is indicated on the sacreen for approx. 20 sec.onds. If no press of probe is made during this period, the unit returns to status before pressing △ or ▽ key automatically To calibrate again , try again from the beginning of the process of Calibration Standard Equate a displayed value with Thic ness standard with △...
  • Page 27 In case of ○ A : The buzzer beeps, beeps. 【Cal.w.foil】 Ready for measure. (Fe) This uni is now ready for taking mesurements and adjustments. ー Cal. No. 7 ■ μm In case of ○ B : Press the probe to the object for measurements. (Fe) Measuring mode Cal.
  • Page 28: 7) 2-Foils Calibration When 「Zeroing」Is Difficult To Perform

    (7) 2-foil calibration when “Zeroing “ is difficult to perform. In case zeroing is difficult to perform such as measuring the thickness of the film on the rough surface of Blast-steel plates, a calibration method using 2 different thicknesses of standard plates pinching a thickness of the object is defined as 「JIS K5600」Standard.
  • Page 29 *Try measuring plural times in range of 2―10 times by pressiing the probe on a thinner 「Thickness Standard」. ( a measuring result is indicated whenever the probe is pressed ) Press ZERO key afterwards. *When repeating measurements 10 times, the buzzer beeps, beeps The buzzer beeps, beeps.
  • Page 30 The buzzer beeps. Press the probe on the thicker 「Thickness Standard」 stacked on the 【2 - foils’ cal】 aforementioned 「Zero plate」 during this message being on the display Measure thicker (about 20 seconds). foil on metal several times. Afterwards, press ZERO . The buzzer beeps whenever pressing the probe.
  • Page 31 【2 - f. c. 】 (Fe) Last measured v alue Cal. No. 3 μm Equate the displayed value with the thickness of Thickness Standard (in this example 200 μm) by pressing key. ▲ 【2 - f. c. 】 (Fe) ▲ A press of key increases a reading value.
  • Page 32 The buzzer beeps, beeps. The unit is now ready to take mesurements and adjustments. (Fe) ー μm Cal. No. 3 ▲ This mark shows that 「Special Adjustment」 data is stored in this number in Calibration. ● It is correct that numerical values measured by pressing the probe to the 「Thickness Standard」 placed on the base like a blast steel plate ndicate 「0」...
  • Page 33: 8) How To Delete Calibration

    (8) How to delete calibration Take the following procedures to delete calibration when the reading on the screen is locked or after batteries replaced or when it becomes impossible to process 「Zeroing」、「Calibration Standard」(CAL). Select 「Cal.No. 」 (Calibration) stroring 「Zeroing value」 and 「Thickness Standard Value」 which you want to delete.
  • Page 34: Function Switching

    Function switching (1)Switching to Noninterrupt Measurement Mode Switch to「non-interrupt measurement mode」when it is necessary to slide a probe along the measuring surface of a substrate as illustrated on the right figure Substrate for continuous measurements of films. A measuring value is indicated and stored (Fe) each time a probe is pressed in a normal state.
  • Page 35 Caution Note that this measuring method may damage the measuring surface or the probe tip due to sliding frictions. Please try fewer to take this method to minimize the frictions. 《Returning to the beginning》 To return 「non-interrupt measurement mode」 to the beginning take the same procedures as at the initial setting.
  • Page 36: 2)Switching Resolution

    (2)Switching to Resolution To inspect precisely a thickness up to 500μm it is possible to take solution measurements by switching to a 0.1μm(0~400μm) unit , to a 0.5μm(400 ~ 500μm) unit. In this case it changes resolution units by taking the following procedures. ●...
  • Page 37: 3)Switching To Key Lock Mode

    (3) Switching to Key Lock Mode This is to prevent this unit from making errors by inadvertently fingering a key in taking measures. ● Press LOCK/DELETE key when Power is On. The buzzer beeps. Any prress of keys except ON/OFF key locks the operation to be non-operational to avoid errors.
  • Page 38: Measuring

    Measuring Please use a hand strap to pass your wrist through to prevent a unit from dropping. According to explanations on page 11 hold a probe and quickly press it to a measuring object. The buzzer beeps. (Fe) A measured result is indicated. 125...
  • Page 39 Setting high/low limits value To judge quickly if the coated film thickness of a product stays within a range of thicknesses corresponding to management standards and controls, it is necessary to set high/low limits beforehand and if the numerical value on display exceeds the limits, the number flashes and emits a warning sound.
  • Page 40 (Fe) A low limit value setting column flashes. 125 μm ■ Cal. No. 1 Lmt. H : 1 5 0 μm L : - - - μm When no low limit setting is necessary, press H/L key without pressing ▲ key.
  • Page 41 (3) Deleting a set limit value. Select a 「Calibration No: 」 storing limit values to be deleted. Refer to (How to select 「calibration No: 」) on page 14. (Fe) 125 μm Cal. No. 8 ■ Lmt. H : 1 5 0 μm L : 1 0 0 μm Hold H/L key and press DATA ERASE key.
  • Page 42 Measurements with High・Low limit values 1) Within a range of limit values The buzzer beeps. (Fe) 137 μm Cal. No. 8 ■ Lmt. H : 1 5 0 μm L : 1 0 0 μm (2) When a measured value goes over a high limit value The buzzer beeps, beeps, beeps beeps, beeps beeps.
  • Page 43: Storing Measured Data

    Storing measured data SWT-7200Ⅱ stores Max. 10, 000 data. Places to store are listed as below. Sections: A section stores 10 data. There are numbers indicated in each 「Places to store data」 Blocks: A block contains 10 「Sections」. Each section has each independent number. Groups :...
  • Page 44 (1) How to select a data storing place (Fe) In this example: A setting is made when storing data from the following - Group number: 「3」 Block number: 「12」 μm Section number: 「1」 Cal. No. 1 ■ And a storing number per section is set at 「8」. Press MEM.-SEL key.
  • Page 45 (Fe) A group No.「3」 is set. Then moving on to setting a Block No. - μm Flashes. Cal. No. 1 ■ memNo. Press ▲ key or ▼ key to select a Block No.「12」. (Fe) - μm Cal. No. 1 ■ Flashes.
  • Page 46 Press MEM.-SEL key. The buzzer beeps. A Section No.「1」 is set. (Fe) Then moving on to setting a storing number in one section. - μm Flashes. Cal. No. 1 ■ memNo. 1 S: Press ▲ key or ▼ key to select a storing number 「8」. (Fe)...
  • Page 47 (Fe) - μm Flashes Cal. No. 1 ■ ※ Note memNo. 1 S: Pressing twice MEM.-SEL key turns the screen to Press MEM.‐SEL key.※ a stage of 「Data is not stored」 and then 「Data storing The buzzer beeps. place」 disappears on the screen. To store measured data press MEM.-SEL key 6 times successively and 「Data storing place」...
  • Page 48 Measurements in storing data ● Prepare this unit for measuring in storing data with 「Data is stored」 on the screen. Measured data are stored in the following steps: (Fe) Data are stored in order into a 「Group No. : 3」, -...
  • Page 49 The following measurement is taken. The buzzer beeps. (Fe) A measured result is indicated. 106 μm Cal. No.1 ■ The number in a storing place returns to 「1」. memNo. 2 S: When 「Section No: 1」 is filled, it moves in order on to 「Section No.:...
  • Page 50 When reaching to a 「Block No.: 20」、a 「Section No.: 10」、 A 「Data No.: 8」 : (Fe) 104 μm Cal. No. 1 ■ A storing place number turns 「8」. memNo. 1 0 S: A section number turns 「10」. A block number turns 「20」. A measurement is taken.
  • Page 51 (Fe) 101 μm Cal. No. 1 ■ A storing place turns 「8」. memNo. 1 0 S: A section number turns 「10」. A block number turns 「20」. A group number turns 「5」 A measurement is taken. The buzzer beeps. All the memory is...
  • Page 52 (2) Looking for an empty storing place ● Interrupt measuring. ● According to 「How to select a data storing place」 procedures on page 40 , select an unoccupied place. (Fe) If data is stored in a selected place, the value is 101...
  • Page 53 Storing Measuring Data at Non-Interrupt Measurment Mode It is possible to store data in a prescribed storing place by sampling data in the following methods when this unit is set at Functions of 「Storing Measuring Data and 「Non-Intrrupt Measuring Mode」 described on page 30. Select a data storing place according to procedures 「Select a data storing place」describe on page 40.
  • Page 54 Deletion of a piece of data Inadvertently pressing a probe against objectives、poor and unstable press on objects make erroneous data which are stored can be deleted. Erroneous value is indicated. (Fe) 853 μm Cal. No. 1 ■ memNo. 1 S: 1 0 : Press DATA ERASE key.
  • Page 55 Deletion of all data When data stored in a storing place are no more necessary, it is possible to delete it and store new data. (deletion of data) (1) Deletion of 『all data』 stored (Fe) (Indication example) 302 Caution μm Make sure that a data storing column is Cal.
  • Page 56 「 - 」 mark is indicated. (Fe) - μm In a data storing place, the following indications turn to (1).: Cal. No. 1 ■ 「Group No.」 「Block No.」 memNo. 1 S: 1 0 : 「Section No.」 「Data No.」 A data number per section turns to the initial stage 「10 」. -52-...
  • Page 57 Deletion of data (group) (2)Deletion of data stored in a 『Group No.』 Group numbers: 1~5 (SWT-7200Ⅱ) (Fe) (Indication example) 302 Caution μm Make sure that an indication colum is Cal. No. 1 ■ indicated. When the indication colums Is not indiated, pre MEM-SEL key memNo.
  • Page 58 Select a group no. in which to delete data by pressing ▲ key or ▼ key (Fe) 302 μm Cal. No. 1 ■ memNo. 5 6 S: 1 0 : Press MEM.CLEAR key. Select a group No. 「5」 The buzzer beeps, beeps. DELETE?...
  • Page 59 The buzzer beeps, beeps. (Fe) 「-」 mark is indicated. - μm In an indication column of a data storing place, Cal. No. 1 ■ the indications are as follows: 「Group No.」: 「5 」 memNo. 1 S: 1 0 : 「Block No.」: 「1 」 「Section No.」:...
  • Page 60 Deletion of data (block) (3) Deletion of data stored in a 『Block No.』 in a group. Block numbers: 1~20 (SWT-7200Ⅱ) (Fe) (Indication example) 403 μm An indication column of a data storing place is indicated. Cal. No. 2 ■ memNo. 3 S: 1 0 : Press MEM.
  • Page 61 (Fe) 256 μm Cal. No. 2 ■ memNo. 3 S: 1 0 : Select a 「Group No 1.」 Press MEM.-SEL key. The buzzer beeps. (Fe) 256 μm Cal. No. 2 ■ memNo. 3 S: 1 0 : 「Group No.」 is set at 「1」, and 「Block No.」...
  • Page 62 DELETE ? All data in: B = 12 【in G = 1】 Press MEM. CLEAR key. DELETE? All data in: B = 12 【In G = 1】 The buzzer beeps, beeps. 「-」 mark is indicated. (Fe) - μm In an indication column of a data storing place, Cal.
  • Page 63 Deletion of data (section) (4) Deletion of data stored in a 『Section No』 in a block in a group. Section numbers: 1~10 (SWT-7200Ⅱ) (Fe) (Indication example) 403 μm Cal. No. 2 ■ An indication column in a data storing place is indicated. memNo.
  • Page 64 Note: When deleting data stored in a 「 section: 5 」 (Fe) included in a block 「7」 of a group No. 「3」. 500 μm Cal. No. 2 ■ memNo. 3 S: 1 0 : Select 「Group No 3.」: flashes. Press MEM.-SEL key.
  • Page 65 Press MEM.-SEL key. The buzzer beeps. (Fe) μm Cal. No. 2 ■ Select a section No. 「5」 memNo. 5 S: 1 0 : Press MEM. CLEAR key. The buzzer beeps, beeps. ERASE All data in: S = 5 【in B=7<G=3】 Press MEM.
  • Page 66 The buzzer beeps. (Fe) 「-」 mark is indicated. _____ μm Cal. No. 2 ■ The following data are indicated: 「Group No.」: 「3」 「Block No.」: 「7」 memNo. S: 1 0 : 「Section No.」:「5」 「Data No.」: 「1」 A total data number per section turns to 「10」. -62-...
  • Page 67 Statistics (1) Statistics of 『all data』 stored (statistical calculation value of data is indicated) (Fe) 107 μm Information in a storing place is indicated. Cal. No. 1 ■ memNo. 5 S: 1 0 : Press STATIS-TICS key. The buzzer beeps, beeps. Caution The message is indicated for bout 20 sec.
  • Page 68 (2)Statistics of data stored in 『Group No.』. Group numbers : 1~5 (SWT-7200Ⅱ) (Fe) In case of statistical operations of data stored in 107 a group number 「3」. μm Information in a storing place is indicated. Cal. No. 1 ■ memNo. S: 1 0 : Press STATIS-TICS key.
  • Page 69 (Fe) In case of statistical operations of data stored in 107 a group number「3」 μm Information in a storing place is indicated. Cal. No. 1 ■ memNo. 5 S: 1 0 : Select a group No.「3」. Press STATIS-TICS key. The buzzer beeps, beeps. Statistics...
  • Page 70 (3)Statistics of data stored in a 『Block No.』 of a group Block numbers : 1~20 (SWT-7200Ⅱ) (Fe) In case of statistical operations of data stored in a block no. 「14」 of a group No. 「1」. 107 μm Cal. No. 1 ■...
  • Page 71 (Fe) 107 μm Cal. No. 1 ■ memNo. S: 1 0 : Select a group No. 「1」. Press MEM.-SEL key. The buzzer beeps. (Fe) 107 In case of statistical operations of data stored in a block No. 「14」 of a group No.「1」. μm...
  • Page 72 Press STATIS-TICS key. The buzzer beeps, beeps (under process of calculations), beeps. VALUE;【 B = 14 】 【 in G = 1 】 Note :Keeping STATIS-TICS key from being #-data : 5 0 pressed and left alone, the stage unchanges remained Mean...
  • Page 73 (4) Statistics of data stored in a 『Section No.』 in a block of a group. Section numbers: 1~10 (SWT-7200Ⅱ) (Fe) In case of data stored in a section no.「1」 in a block No. 「2」 of a group No.「5」. 107 μm Information in a storing place is indicated.
  • Page 74 (Fe) 107 μm Cal. No. 1 ■ memNo. 5 S: 1 0 : Select a group No.「5」. Press MEM.-SEL key. The buzzer beeps. (Fe) 107 μm Cal. No. 1 ■ memNo. 5 S: 1 0 : A group no.「5」 is set and a block No. flashes. Press ▲...
  • Page 75 Press ▲ key or ▼ key to equate with a section No. to calculate statistics. (Fe) 107 μm Cal. No. 1 ■ memNo. 1 S: 1 0 : Select a section No.「1」. Press STATIS-TICS key. A section No. flashes. The buzzer beeps, beeps. Caution Statistics...
  • Page 76: Transferring Data

    Transferring dataー① (USB) Transfer data to a PC (personal computer) by using a USB cable Refer to separately attached information for arrangements to install a driver into a PC side. If this unit is set at 「Non-Interrupt Measurement Mode」, Data-transfer can not be used . Please make sure that the unit is set at ordinary measurement mode.
  • Page 77 (2) Interrupt transferring data (Fe) 101 μm USB Cal. No. 1 ■ memNo. 5 S: 1 0 : Press COM.ENABLE key. The buzzer beeps. (Fe) 101 A reversal display USB disappear on screen. μm Data stops being transferred. Cal. No. 1 ■...
  • Page 78 Transferring stored dataー② (USB) (3) Transferring stored 『all data』. ● Prepare for a PC side ● Connect a USB cable to a PC. (Fe) 101 μm Cal. No. 1 ■ memNo. 5 S: 1 0 : Press COM.ENABLE key. The buzzer beeps. (Fe)...
  • Page 79 Press TRANS-MIT key. The buzzer beeps, beeps. TRANSMITTING. all data in; 《 Transferring has completed 》 The buzzer beeps. (Fe) Returning to the beginning. 101 μm Cal. No. 1 ■ memNo. 5 S: 1 0 : -75-...
  • Page 80 Transferring stored dataー③ (USB) (4) Transferring data stored in a 『Group No.』. ● Prepare for a PC side. ● Connect a USB cable to a PC. (Fe) 101 μm Cal. No. 1 ■ memNo. 5 S: 1 0 : Press COM.ENABLE key.
  • Page 81 Press MEM.-SEL key. The buzzer beeps. (Fe) 101 In case of transferring data stored in a group no.「3」 μm A group No. flashes. USB Cal. No. 1 ■ memNo. 5 S: 1 0 : Press ▲ key or ▼ key to equate with the group No.
  • Page 82 TRANSMITTING all data in; 《Transferring has completed 》 The buzzer beeps. (Fe) Returning to the beginning. 101 μm Cal. No. 1 ■ memNo. 5 S: 1 0 : -78-...
  • Page 83 Transferring stored data ー④ (USB) (5) Transferring data stored in a 『Block No.』 of a group ● Prepare for a PC side. ● Connect a USB cable to a PC. (Fe) 101 μm Cal. No. 1 ■ memNo. 5 S: 1 0 : Press COM.ENABLE key.
  • Page 84 (Fe) 101 μm The group No. flashes. USB Cal. No. 1 ■ memNo. 5 S: 1 0 : Press ▲ key or ▼ key to equate with the group No. (Fe) In case of transferring data stored in a block No.「7」 101...
  • Page 85 Press TRANS-MIT key. The buzzer beeps, beeps. TRANSMIT ? all data in; 【 in G = 4 】 Press TRANS-MIT key. The buzzer does not beep. TRANSMITTING all data in; 【 in G = 4 】 《 Transferring has completed 》 The buzzer beeps.
  • Page 86 Transferring stored dataー⑤ USB (6) Transferring data stored in a 『Section No.』 in a block of a group. ● Prepare for a PC side. ● Connect a USB cable to a PC. (Fe) 101 μm Cal. No. 1 ■ memNo. 5 S: 1 0 : Press COM.ENABLE key.
  • Page 87 (Fe) In case of transferring data stored in a section 「1」 in a block no.「8」 of a group no.「5」. 101 μm USB Cal. No. 1 ■ A group no. flashes. memNo. 5 S: 1 0 : Press ▲ key or ▼ key to equate with a group No. (Fe)...
  • Page 88 (Fe) 101 μm USB A block no. is set at 「8」. Cal. No. 1 ■ A section No. flashes. memNo. 5 S: 1 0 : Press ▲ key or ▼ key to equate with a section No. (Fe) 101 μm Equate with a section No.「1」...
  • Page 89 《 Transferring has completed 》 The buzzer beeps. (Fe) Returning to the beginning. 101 μm Cal. No. 1 ■ memNo. 5 S: 1 0 : -85-...
  • Page 90 Note to improve measuring accuracy ① Zero plate Prepare the same material, thick and sized plate as the measuring object for zeroing and calibration standard (CAL). Different materials may not bring about correct measuring results. * As accessories to probe, “zero plates for zeroing” 「for electromagnetic: SUS-430」 (ferrite stainless), 「for eddy current: AL1050 ( aluminum )」...
  • Page 91: Trouble Shooting

    Trouble Shooting Before contacting us please check with the following points. Symptoms Points to check Measures to be taken No response upon press of Are batteries worn out? Replace them with new ones (2 ea.) ON/OFF key. No response after replacing Something wrong inside a meter Contact us for repair batteries and pressing a key...
  • Page 92 Symptoms Points to check Measures to be taken Probe may be broken. Contact our office for repair Trouble ! at your convienience. Something wrong with probe. Replace with new one. 《Power OFF》 Eiither probe and unit may Contact our office for repair Trouble ! be faulty.
  • Page 93 Symptoms Points to check Measures to be taken USB cable transfer is not working. ① Connections of USB cable ①Be sure of connecting USB cable ② PC is not ready to work with ②(1)Correctly install Driver according ito instructions of attached CD (2)Corectly set Vertial /Com Port USB transfer is suddenly...
  • Page 94: Specifications

    Specifications ◆ Unit Items Applications Model names Dual electromagnetic/eddy current (SWT-7200Ⅱ) Display method Graphic LCD (data ・ message) Ranges Depending on optional probes Calibrations 2 points calibration type Zeroing : for substrate (CAL) Calibration standard : for substrate and standard thicknesses ①...
  • Page 95 ◆ Probes (Optional) Models Fe-2.5/Fe-2.5 L NFe-2.0 /NFe-2.0 L NFe-0.6 Methods Magnetic inducing type Eddy current type Ranges 0~2.50mm 0~2.00mm 0~600μm 1μm:0~999μm 1μm:0~999μm 1μm:0~600μm switching to switching to 0.1μm:0~400μm、 0.1μm:0~400μm、 Display resolutions switching to 0.5μm:400~500μm 0.5μm:400~500μm 0.1μm:0~400μm、 0.5μm:400~500μm 0.01mm:1.00~2.50mm 0.01mm:1.00~2.00mm 0~100μm:±1μm...
  • Page 96 Reference (Principle of measurements) Electro-Magnetic type ● When metals approach to AC- magnetic fields emitted from probe, the metal and the magnet pull each other. It makes the pulling force stronger as they come closer. In other words, it makes the magnetic density higher as they come closer.
  • Page 97 Sales of Coating thickness meter, Pinhole detector, Condensator, Viscosity cup, Moisture meter, Needle detector, Iron piece detector Manufacturer: Sanko Electronic Laboratory Co., Ltd. Tokyo branch:Shibata Bldg., 2-6-4, Uchikanda, Chiyoda-ku, Tokyo 101-0047, Japan Tel 81-3-3254-5031 Fax 81-3-3254-5038 Osaka branch:Konishi Bldg., 2-3, Sugawara-cho, Kita-ku, Osaka 530-0046, Japan Tel 81-6-6362-7805 Fax 81-6-6365-7381 Nagoya branch:Meihoku Bldg., 3-11-27, Kinjo, Kita-ku, Nagoya 462-0847, Japan...