When a notification of the remaining capacity of the SD memory card has been provided ("Diag.")
When the SD memory card has become full ("Diag.")
When the SD memory card cannot be recognized ("Diag.")
Default: Off
Note
When "On" is selected, notification of the alarm occurrence will be provided to the registered destination
server addresses in order (to IP address 1 first, to IP address 8 last).
[Additional alarm data]
Determine whether or not to send notifications for VMD alarm detection area numbers with the Panasonic
alarm protocol by selecting On/Off.
Default: Off
[Destination port]
Select a destination port for the Panasonic alarm protocol from the following.
Available range: 1 - 65535
Default: 1818
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 995, 10669, 10670
[Retry times]
Select a retry time for the Panasonic alarm protocol.
Available range: 0-30
Default: 2
Destination of notification
[Address 1] - [Address 8]
Enter the destination IP address or host name of the Panasonic alarm protocol from the following. Up to 8
destination server addresses can be registered.
[Alarm] checkbox: When the checkbox is checked, the Panasonic alarm notification will be provided upon
an alarm occurrence.
[Diag.] checkbox: When the checkbox is checked, notification using Panasonic alarm protocol will be
provided in the following cases.
When notification of the remaining capacity of the SD memory card has been provided
When the SD memory card has become full
When the SD memory card cannot be recognized
[Destination server address]: Enter the destination server address or host name.
Available characters: Alphanumeric characters, the colon (:), the period (.), the underscore (_), and
the hyphen (-).
To delete the registered destination server address, click the [Delete] button respective to the desired
destination server address.
[Auto track cooperation]
Select whether to perform auto track cooperation setup by selecting On/Off.
When "On" is selected for "Auto track cooperation", alarm notification is only implemented when the number
of the "Alarm area" set in auto track alarm conforms with the alarm area number. Alarm notifications other than
auto track alarms are not implemented.
When using auto track cooperation, set "Auto track alarm" to "On(In preset alarm area)" in the auto tracking
settings. (®Page 130)