HP 54753A User Manual page 158

Plug-in modules
Table of Contents

Advertisement

Measuring Differential Impedance
1
2
Figure 8-5
1
2
3
4
5
Differential TDR Measurements
Measuring Differential and Common Mode Impedance
We are now ready to measure the differential impedance of the differential line.
Connect the channel 1 cable to the differential line closest to the edge
of the board.
Connect the channel 2 cable to the other differential line (Figure 8-5).
Make sure that the switch on the demo board is in the off position
(toward the outside edge of the board away from the differential line).
Press the
blue
key followed by the
Press the
SETUP Time base
Change the
to 500 ps/div.
Scale
Change the
Position
until the reflected steps are in the middle of the
display (Figure 8-6).
8-10
Clr
key.
key.