Installation Guide CF-MC Master Controller
8. Technical Specifications
8.1 CF-MC Master Controller
Transmission frequency
Transmission range in normal constructions (up to)
Transmission power
Supply voltage
Actuator outputs
Max. continued output load (total)
Relays
Ambient temperature
IP class
8.2 CF-RS, -RP, -RD and -RF Room Thermostats
Temperature setting range
Transmission frequency
Transmission range in normal constructions
(up to)
Transmission power
Battery
Battery lifetime (up to)
Ambient temperature
IP class
Floor sensor accuracy*
Floor sensor emission coefficient*
* Only valid for CF-RF Room Thermostat
Note! See separate instructions for other components.
Danfoss Heating Solutions
868.42 MHz
30 m
< 1 mW
230 V AC
10 x 24 V DC
35 VA
230 V AC/8 (2) A
0 - 50 °C
30
5 - 35 °C
868.42 MHz
30 m
< 1 mW
Alkaline 2 x AA, 1.5 V
1 to 3 years
0 - 50 °C
21
+/- 1 °C
0.9
VIUHK902
GB
01/2016