GE B30 Instruction Manual page 415

Multilin b30 bus differential system ur series
Hide thumbs Also See for B30:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 8 of 60)
ADDR
REGISTER NAME
270E
IEC 61850 received uinteger 16
Expanded FlexStates (Read Only)
2B00
FlexStates, one per register (256 items)
Expanded Digital Input/Output states (Read Only)
2D00
Contact Input States, one per register (96 items)
2D80
Contact Output States, one per register (64 items)
2E00
Virtual Output States, one per register (96 items)
Expanded Remote Input/Output Status (Read Only)
2F00
Remote Device States, one per register (16 items)
2F80
Remote Input States, one per register (64 items)
Oscillography Values (Read Only)
3000
Oscillography Number of Triggers
3001
Oscillography Available Records
3002
Oscillography Last Cleared Date
3004
Oscillography Number Of Cycles Per Record
Oscillography Commands (Read/Write Command)
3005
Oscillography Force Trigger
3011
Oscillography Clear Data
3012
Oscillography Number of Triggers
User Programmable Fault Report Commands (Read/Write Command)
3060
User Fault Report Clear
User Programmable Fault Report Actuals (Read Only)
3070
Newest Record Number
3071
Cleared Date
3073
Report Date (10 items)
User Programmable Fault Report (Read/Write Setting) (2 modules)
3090
Fault Report 1 Fault Trigger
3091
Fault Report 1 Function
3092
Fault Report 1 Prefault Trigger
3093
Fault Report Analog Channel 1 (32 items)
30B5
Fault Report 1 Reserved (5 items)
30BA
...Repeated for Fault Report 2
Modbus file transfer (read/write)
3100
Name of file to read
Modbus file transfer values (read only)
3200
Character position of current block within file
3202
Size of currently-available data block
3203
Block of data from requested file (122 items)
Security (Read Only)
328A
Administrator alphanumeric password status
Security (Read Only)
329F
Supervisor alphanumeric password status
Security (Read Only)
32B4
Engineer alphanumeric password status
Security (Read Only)
32C9
Operator alphanumeric password status
Security (Read Only)
32DE
Observer alphanumeric password status
GE Multilin
RANGE
0 to 4294967295
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 65535
0 to 65535
0 to 400000000
0 to 65535
0 to 1
0 to 1
0 to 32767
0 to 1
0 to 65535
0 to 4294967295
0 to 4294967295
0 to 65535
0 to 1
0 to 65535
0 to 65536
---
---
0 to 4294967295
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
B30 Bus Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F003
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F155
---
1
F108
---
1
F001
---
1
F001
---
1
F050
---
1
F001
---
1
F126
---
1
F126
---
1
F001
---
1
F126
---
1
F001
---
1
F050
---
1
F050
---
1
F300
---
1
F102
---
1
F300
---
1
F600
---
---
F001
---
---
F204
---
1
F003
---
1
F001
---
1
F001
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
DEFAULT
0
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Offline)
0 (Off)
B
0
0
0
0
0 (No)
0 (No)
0
0 (No)
0
0
0
0
0 (Disabled)
0
0
0
(none)
0
0
0
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (Disabled)
B-15

Advertisement

Table of Contents
loading

Table of Contents