B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 39 of 60)
ADDR
REGISTER NAME
AA02
IEC 61850 GOOSE analog input 1 mode
AA03
IEC 61850 GOOSE analog input 1 units
AA05
IEC 61850 GOOSE analog input 1 per-unit base
AA07
...Repeated for IEC 61850 GOOSE analog input 2
AA0E
...Repeated for IEC 61850 GOOSE analog input 3
AA15
...Repeated for IEC 61850 GOOSE analog input 4
AA1C
...Repeated for IEC 61850 GOOSE analog input 5
AA23
...Repeated for IEC 61850 GOOSE analog input 6
AA2A
...Repeated for IEC 61850 GOOSE analog input 7
B
AA31
...Repeated for IEC 61850 GOOSE analog input 8
AA38
...Repeated for IEC 61850 GOOSE analog input 9
AA3F
...Repeated for IEC 61850 GOOSE analog input 10
AA46
...Repeated for IEC 61850 GOOSE analog input 11
AA4D
...Repeated for IEC 61850 GOOSE analog input 12
AA54
...Repeated for IEC 61850 GOOSE analog input 13
AA5B
...Repeated for IEC 61850 GOOSE analog input 14
AA62
...Repeated for IEC 61850 GOOSE analog input 15
AA69
...Repeated for IEC 61850 GOOSE analog input 16
AA70
...Repeated for IEC 61850 GOOSE analog input 17
AA77
...Repeated for IEC 61850 GOOSE analog input 18
AA7E
...Repeated for IEC 61850 GOOSE analog input 19
AA85
...Repeated for IEC 61850 GOOSE analog input 20
AA8C
...Repeated for IEC 61850 GOOSE analog input 21
AA93
...Repeated for IEC 61850 GOOSE analog input 22
AA9A
...Repeated for IEC 61850 GOOSE analog input 23
AAA1
...Repeated for IEC 61850 GOOSE analog input 24
AAA8
...Repeated for IEC 61850 GOOSE analog input 25
AAAF
...Repeated for IEC 61850 GOOSE analog input 26
AAB6
...Repeated for IEC 61850 GOOSE analog input 27
AABD
...Repeated for IEC 61850 GOOSE analog input 28
AAC4
...Repeated for IEC 61850 GOOSE analog input 29
AACB
...Repeated for IEC 61850 GOOSE analog input 30
AAD2
...Repeated for IEC 61850 GOOSE analog input 31
AAD9
...Repeated for IEC 61850 GOOSE analog input 32
IEC 61850 XCBR configuration (read/write settings) (6 modules)
AB00
Operand for IEC 61850 XCBR1.ST.Loc status
AB02
Command to clear XCBR1 OpCnt (operation
counter)
AB03
Operand for IEC 61850 XCBR2.ST.Loc status
AB06
Operand for IEC 61850 XCBR3.ST.Loc status
AB09
Operand for IEC 61850 XCBR4.ST.Loc status
AB0C
Operand for IEC 61850 XCBR5.ST.Loc status
AB0F
Operand for IEC 61850 XCBR6.ST.Loc status
IEC 61850 LN name prefixes (read/write settings)
AB30
IEC 61850 logical node LPHD1 name prefix
AB33
IEC 61850 logical node PIOCx name prefix (72
items)
AC0B
IEC 61850 logical node PTOCx name prefix (24
items)
B-46
RANGE
0 to 1
---
0 to 999999999.999
0 to 4294967295
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65534
0 to 65534
0 to 65534
B30 Bus Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F491
---
---
F207
---
0.001
F060
---
1
F300
---
1
F126
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F206
---
1
F206
---
1
F206
DEFAULT
0 (Default
Value)
(none)
1
0
0 (No)
0
0
0
0
0
(none)
(none)
(none)
GE Multilin