GE B30 Instruction Manual page 430

Multilin b30 bus differential system ur series
Hide thumbs Also See for B30:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 23 of 60)
ADDR
REGISTER NAME
4E18
Raw Field Data DC1
4E19
Raw Field Data DC2
4E1A
Raw Field Data DC3
4E1B
Raw Field Data FCI States (2 items)
4E1D
Raw Field Data SI States
4E1E
Raw Field Data SI Test States
4E1F
Raw Field Data Brick ADC Temperature
4E20
Raw Field Data Brick Transceiver Temperature
4E21
Raw Field Data Brick Transceiver Voltage
4E22
Raw Field Data Brick Transceiver Current
B
4E23
Raw Field Data Brick Tx Power
4E24
Raw Field Data Brick Rx Power
4E25
Raw Field Data Brick Diagnostics (2 items)
4E27
Raw Field Data Local Transceiver Temperature
4E28
Raw Field Data Local Transceiver Voltage
4E29
Raw Field Data Local Transceiver Current
4E2A
Raw Field Data Local Tx Power
4E2B
Raw Field Data Local Rx Power
4E2C
Repeated for module number 2
4E58
Repeated for module number 3
4E84
Repeated for module number 4
4E80
Repeated for module number 5
4EDC
Repeated for module number 6
4F08
Repeated for module number 7
4F34
Repeated for module number 8
Flexlogic (Read/Write Setting)
5000
FlexLogic Entry (512 items)
RTD Inputs (Read/Write Setting) (48 modules)
5400
RTD Input 1 Function
5401
RTD Input 1 ID
5407
RTD Input 1 Type
5414
...Repeated for RTD Input 2
5428
...Repeated for RTD Input 3
543C
...Repeated for RTD Input 4
5450
...Repeated for RTD Input 5
5464
...Repeated for RTD Input 6
5478
...Repeated for RTD Input 7
548C
...Repeated for RTD Input 8
54A0
...Repeated for RTD Input 9
54B4
...Repeated for RTD Input 10
54C8
...Repeated for RTD Input 11
54DC
...Repeated for RTD Input 12
54F0
...Repeated for RTD Input 13
5404
...Repeated for RTD Input 14
5518
...Repeated for RTD Input 15
552C
...Repeated for RTD Input 16
5540
...Repeated for RTD Input 17
5554
...Repeated for RTD Input 18
5568
...Repeated for RTD Input 19
B-30
RANGE
0 to 0.001
0 to 0.001
0 to 0.001
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 0.01
0 to 1
0 to 0.01
0 to 0.1
0 to 65535
0 to 1
0 to 0.01
0 to 1
0 to 0.1
0 to 0.1
0 to 4294967295
0 to 1
---
0 to 3
B30 Bus Differential System
APPENDIX B
UNITS
STEP
FORMAT
V
0.001
F002
V
0.001
F002
V
0.001
F002
---
1
F500
---
1
F500
---
1
F500
degree
1
F002
degree
1
F002
V
0.01
F001
mA
1
F001
dBm
0.1
F002
dBm
0.1
F002
---
1
F500
degree
1
F002
V
0.01
F001
mA
1
F001
dBm
0.1
F002
dBm
0.1
F002
---
1
F300
---
1
F102
---
---
F205
---
1
F174
DEFAULT
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2097152
0 (Disabled)
"RTD Ip 1"
0 (100 ohm
Platinum)
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents