Unit Specifications - Cornelius Millennium II 6000 Installation Manual

6 flavor post-mix juice dispenser
Hide thumbs Also See for Millennium II 6000:
Table of Contents

Advertisement

Model Number
Electrical Ratings:
Electrical Connection:
Water Requirements:
Refrigeration:
Test Pressures:
Recommended Clearance:
Weight:
Concentrate Supply Line Length:
Approvals:
© 2003-2013, IMI Cornelius Inc.

UNIT SPECIFICATIONS

17.600
(447,04)
32.048
(814,03)
12.523
(318,1)
10.389
(263,88)
9.090
(230,89)
Figure 1.
Millennium II 6000
115 VAC / 1 Phase / 60HZ / 11.1 Amps
230 VAC / 1 Phase / 60HZ / 5.50 Amps
230 VAC / 1 Phase / 50HZ / 6.0 Amps
115V 3 Prong Plug with Ground (supplied)
230V 2 Prong Plug (supplied)
15 Amp Receptacle with Ground
15 Amp Circuit Breaker
3/8 (9.5 mm) SAE Male Flare Inlet
Minimum 20 psig (1.4 Bar)
Recommended 40 psig (2.8 Bar)
Maximum 60 psig (4.14 Bar)
7.0 oz. (198.4 g) R-134A Refrigerant, 1/3+ HP Compressor
High: 230 psig (15.8 Bar)
Low: 90 psig (6.2 Bar)
Air Cooled Condenser
18 in. (46 cm) Above Dispenser
6 in. (16 cm) At Side Panel Vents
Shipping: 140 lbs. (63.5 kg)
Operating: 220 lbs. (100 kg)
50 feet (15.2 m) Total Maximum
15 feet (4.5 m) Vertical Maximum
UL
CUL
NSF