15. Apply Sealant to Base and Countertop
If the legs supplied with the dispenser are not used to raise the dispenser off the counter, the entire
perimeter of the base must be sealed at the countertop with silicone (or other food grade approved
sealant) in order to comply with NSF standards.
16. Brixing Concentrate
The following procedures describe how to adjust the water to concentrate ratio (brix) according to taste.
Contact the concentrate supplier for recommended brix ratios.
A. Remove the flavor strips above the dispense valves.
B. Sample the finished drink. Increase or decrease the water ratio by inserting a flat blade screwdriver
into the slot behind the flavor label and turning the water flow control screw clockwise (more water) or
counter–clockwise (less water) until the desired water to concentrate ratio is achieved. Repeat the
procedure on the remaining valves.
C. Replace the flavor strips.
NOTE: If the flow control does not respond, there may be debris caught between the internal
ceramic spool and sleeve. Try dislodging the debris by pressing the dispense switch several times
or by turning the flow control adjustment screw all the way in and out several times.