5-5-2 Automatic protection capping

( E and S machine )
1: Press the "keep-wet down" button , the capping descend( need to press this button
all the time, if loosen the button, the capping will stop immediately
2: When the capping descend the bottom, the buzzer on the panel will alarm,the
capping will automatically stop to descend.
3: The capping in the bottom will automatically connect main power

5-6 Platform Heater:

There are three platforms front heater, bed heater, rear heater which are controlled heating
panel. As shown: