8. FILLING THE FILLING CHAMBER
Take care that the Screens
are not obstructed with plant
material. To guarantee opti-
mal results, we recommend cleaning
the Screens after each vaporization
cycle with the enclosed Cleaning
Brush.
The upper Screen especially can be-
come clogged with plant material and
so make inhaling difficult. In this case,
remove the Screen as described in
Chapter 10. "Disassembling, clean-
ing and assembling", page 23 and
clean or insert a new Screen.
Then re-mount the Cooling Unit by ro-
tating it clockwise through 90°.
As soon as the lower Filling Chamber
Screen is clogged or shows depos-
its, a cleaning of the Filling Chamber
is needed. For that, please firstly re-
move the lower Screen as described
in Chapter 10.3. "Removal of the lower
Filling Chamber Screen", page 26
and clean the Filling Chamber with a
cotton stick that has been soaked in
alcohol. Please make sure that no al-
cohol drops into the inner of the de-
vice. After cleaning, a new Screen is
to be inserted.

8.1. Filling Aid

The Filling Aid supplied with the unit
makes filling the Filling Chamber an
easy and clean operation and serves
as a magazine for transporting and
storing plant material already ground
in the Herb Mill.
To fill the Filling Aid, remove the up-
per cap and fill the bowl incl. plug with
ground plant material. Replace the
upper cap and close it.
Filled Filling Aid
(upper cap removed)
20
8. FILLING THE FILLING CHAMBER
8.2. Filling the Filling Chamber Us-
ing the Filling Aid
Upper
Remove the Cooling Unit from the Va-
Cap
porizer and remove any residues that
may be in the Filling Chamber. The
Filling Chamber Tool can be a help in
Plug
doing this.
Remove the lower cap of the Fill-
ing Aid by turning counterclockwise.
Bowl
Place the Filling Aid on the Vaporizer
and attach by turning it clockwise. Re-
move the upper cap from the Filling
Aid. Pull the plug and use it to fill a por-
tion of plant material through the cen-
Lower
tral opening into the Filling Chamber.
Cap
Make sure that the Filling
Chamber is not overfilled (see
Chapter 8. "Filling the Filling
Chamber", page 19).
Fill the Filling Aid to the lower rim
(see the two following drawings)!
Overfilling leads to clogging of the
Screens and can make inhaling more
difficult.
Filling the Filling Chamber with the Filling
Aid
The lower rim of the Filling Aid must be
above the top level of the plant material
Then re-insert the plug into the central
opening and screw on the upper cap
of the Filling Aid.
Unscrew the Filling Aid with a 90°
rotation and screw on the lower cap
again. Then re-mount the Cooling Unit
by rotating it clockwise through 90°.
21