Heating Up; Temperature Setting - Storz & Bickel GMBH MIGHTY Instructions For Use Manual

Hide thumbs Also See for MIGHTY:
Table of Contents

Advertisement

7. COMMISSIONING AND OPER ATION
The battery can also be
charged via the optional 12
Volt car charger. Connect the
12 Volt car charger to the power sock-
et of the Vaporizer and then plug into
the cigarette lighter or suitable 12 V
socket. Charge and complete the op-
eration in the same way as with the
power adapter (Chapter 7.1. "Charg-
ing the Battery", page 15).
Connecting the Vaporizer using the power
adapter or the 12 Volt car charger
Batteries are specially as-
sembled consumable items
that can only be replaced by
Storz & Bickel when the MIGHTY Va-
porizer is sent in to them.
Any attempt by the customer to re-
place the battery by him/herself is
potentially dangerous and leads to
loss of any claims under the warranty
and exempts Storz & Bickel from any
liability.
Mains Operation
The MIGHTY Vaporizer can also be
operated with the power adapter, even
when the batteries are completely
discharged. Proceed as described in
Chapter 7.1. "Charging the Battery",
page 15 and then connect up the
Vaporizer.
Automatic Switching Off
The automatic switching off is used to
save battery capacity so that the Va-
porizer can be used as long as pos-
sible without charging.
The device switches off automati-
cally two minutes after the last press
of a button or the last application. The
switching off of the Vaporizer is indi-
cated by a short vibration.
A short press of the ON/OFF
switch during operation can
reset the automatic switching-
off to two minutes.

7.2. Heating Up

The MIGHTY Vaporizer provides two
temperature levels that are set in the
factory: The basic temperature at
180°C (356°F) and the booster tem-
perature at 195°C (383°F).
Switch on the device (heating up the
Vaporizer with full Filling Chamber
and Cooling Unit mounted is recom-
mended). To do this, press the orange
ON/OFF switch for at least half a sec-
ond. The Vaporizer responds with a
16
7. COMMISSIONING AND OPER ATION
short vibration. The vibration does not
take place if there is a fault.
The display signals that heating is in
progress by showing the set and ac-
tual temperatures. Set the desired
temperature using the temperature
buttons to the left and right of the set
temperature display. Heating up the
heat exchanger can take up to two
minutes, depending on the set tem-
perature and battery charge level.

7.3. Temperature Setting

Set temperature display
(displayed blinking:
booster temperature)
Minus temperature button
The temperature can be set between
40°C and 210°C (104°F and 410°F)
(see Chapter 4. "Overview of Plants",
page 11).
When you press the plus button, the
set value is increased, and when you
press the minus button, the set value
is decreased. When you briefly tap
on the plus or minus button, the set
values are increased or decreased
respectively in 1-degree increments.
Once the set temperature is reached,
this is signaled by a short double vi-
bration.
If the basic temperature can no longer
provide adequate evaporation, the
booster temperature can be activated
by means of a double-click on the or-
ange-colored ON/OFF switch. Once
the booster temperature is reached,
this is signaled by a short double vi-
bration and a blinking Set Tempera-
ture display.
Actual temperature display
Plus temperature button
Battery charging display
If you keep the plus or minus button
pressed, the set values start running
continuously in the corresponding di-
rection.
The booster temperature can be ad-
justed in the same way. However, it
cannot be set lower than the previous
set temperature.
The current acutal temperature can be
read from the upper line of the display.
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents