3. Intended use ..............9 4. Overview of Plants ............10 5. factors Influencing Vaporization ........11 6. The Hot Air Generators VOLCANO DIGIT and VOLCANO CLASSIC ....12 unpacking, Installation, Application and Operation, Care and Maintenance, Storage, In Case of Problems, Troubleshooting, Technical Specifications 7.
Page 3
Valve Balloon Valve Balloon with Mouthpiece filling Chamber Mouthpiece with Cap Compatible with VOLCANO CLASSIC and VOLCANO DIGIT Compatible with VOLCANO CLASSIC and VOLCANO DIGIT 1. PRODuCT OVERVIEW VOLCANO CLASSIC 1. PRODuCT OVERVIEW VOLCANO DIGIT Hot Air Outlet Hot Air Outlet...
(e.g. strangulation with the power the underside of the Hot Air Gene- Caution! Hot surfaces! cord), thus resulting in a risk of Never leave filling Chamber on VOLCANO Hot Air Generator. rator corresponds to the mains injury. supply at the place of installation.
After use, stances are released through vapor- The VOLCANO Vaporization System is distance from sources of heat (oven, switch off the heater and the air ization by heated air, and may be ex- not intended for medical/therapeutic stove, fireplace etc.) and in a place...
If this occurs, it is urgently rec- Chamber and grind it once again to ated by the fDA. The VOLCANO Va- cause the vapors condense on the ommended to refrain from further use...
Page 7
6. VOLCANO DIGIT AND CLASSIC HOT AIR GENERATORS 5. fACTORS INfLuENCING VAPORIZ ATION Breathing Techniques can normally manage. Hold your breath If you have any concerns, or if there Clean the housing with a soft cloth; or, for a few seconds and then exhale...
DIGIT adjustable between approx. Do not open the Hot Air Ge- the internal fuses may have been triggered. 40°C- 230°C (104°f- 446°f) In this case, send the VOLCANO Hot Air Ge- nerator! Without special tools Air flow: approx. 12 l/min and specialized knowledge, nerator to our Service Center.
“HEAT”. The set/actual tended during operation. Put vaporization. During operation the tem- temperature will light up, signaling the VOLCANO CLASSIC on a perature is measured at the heat ex- that the heater is switched on. flat stable surface.
Never leave the filling Chamber on top loon (overpressure) in order to pre- of the hot air outlet of the VOLCANO Before putting the Valve Bal- vent the loss of vapor of aromas and as long as the heater is on, except loon on the filling Chamber, fragrances.
Mouthpiece The EASY VALVE Balloon and its Caution! Hot surface! Mouthpiece require no maintenance. Never leave Filling Chamber on VOLCANO for hygienic reasons, they should be Detach the Valve Balloon from the fil- replaced with a new Valve Balloon ling Chamber. When you do so, the and Mouthpiece every two weeks.
Clips are loosened and fall out of the dren as it is a potential source filling Chamber Housing. of danger. As an alternative to the VOLCANO Balloon, only use heat-re- Lower Screen sistant, food safe and odor-free oven max. 10 mm tubes and oven bags.
Page 13
10. SOLID VALVE 10. SOLID VALVE Attach the Valve with the affixed Bal- approx. loon to the filling Chamber. To do this, set the Valve onto the filling Chamber 5 sec from above until both grippers are locked in place. The Valve will auto- matically open up.
To inhale, put the Mouthpiece to your leave the filling Chamber on top of lips and press them lightly against the the hot air outlet of the VOLCANO Mouthpiece. By doing so, the Valve when “HEAT” is switched on, except opens and the vapors can be inhaled for filling the Valve Balloon.
Page 15
10. SOLID VALVE 10. SOLID VALVE The Mouthpiece, Valve and filling Remove the Valve Cap and Valve Ring. Chamber are easily disassembled Pull out the Valve Cylinder along with Mouthpiece Cylinder within seconds for cleaning. The com- the Valve Spring of the Valve Hous- ponent parts of the Mouthpiece, Valve ing.
Page 16
Balloon over the Valve Collar BALLOON ADAPTER RESP. SOLID VALVE until it fits into the intended notch. As an alternative to the VOLCANO Balloon, use an odor-free, heat-resis- tant and food safe oven tube or oven bag, which is used in the food indus- try.
(room temperature) plants specified in the plant list. The fore, a very small dosage is VOLCANO and switch on the air pump stainless steel wire of the Liquid Pad sufficient. The vaporized concentra- until the alcohol has evaporated, which...
(36) months by Storz & Bickel GmbH & Co. KG or deterioration, including, but not limi- Liability for VOLCANO DIGIT, VOLCANO or Storz & Bickel America, Inc. (the ted to, defects in Screens, Air filters, CLASSIC, SOLID VALVE and EASY “Company”).
Page 19
14. WARR ANT y, LIABILIT y, REPAIR SERVICE ckel GmbH & Co. KG from any and all Instructions for use are based on liability. our experience and is current and complete to the best of our know- Limitation of Liability ledge and ability at the time of prin- In no event shall Company be liable ting.
Need help?
Do you have a question about the Volcano and is the answer not in the manual?
Questions and answers