  • Page 1 S TO R Z & B I C K E L G M B H & C O. K G INSTRUCTIONS FOR USE Read carefully before using the device and save these instructions.
  • Page 2: Table Of Contents

    Product Overview, Service ..........4 Explanation of Symbols, Safety Recommendations ..6 Intended Use ..............10 Overview of Plants............11 Factors Influencing Vaporization .........12 The Hot Air Generator PLENTY ........12 Commissioning and Operation ........14 7.1. Heating Up ............15 7.2 . Temperature Setting ...........16 Filling the Filling Chamber ...........18...
  • Page 3 1. PRODUCT OVERVIEW PLENTY HOT AIR GENERATOR 1. PRODUCT OVERVIEW PLENTY VAPORIZATION UNIT Vaporization Unit, comprising: Filling Chamber Threading Mouthpiece Auto off Release Handle Thermometer Cooling Coil Power Switch Filling Chamber Cap Control Lamp Temperature Adjustment Wheel Ventilation Slots Filling Chamber...
  • Page 4 Do not touch metal parts! These Instructions for Use are a You may download the current In- significant part of the Vaporizer structions for Use for the PLENTY and must be provided to the user. Keep away from sunlight. on www.storz-bickel.com.
  • Page 5 2. SAFET Y RECOMMENDATIONS 2. SAFET Y RECOMMENDATIONS Safety Recommendations cident prevention measure is not children or unqualified persons. It � The ventilation slots and the hot taken. must not be installed in damp lo- air outlet of the Hot Air Generator � The packaging material (plastic may not be closed, obstructed, or cations (such as bathrooms, etc.).
  • Page 6: Intended Use

    The PLENTY Vaporizer is not a medical of the European or any other pharma- device and is not intended to diagnose, copoeia with regard to genuineness, treat, cure or prevent any disease.
  • Page 7: Factors Influencing Vaporization

    6 . T H E H O T A I R G E N E R AT O R PLENTY 5 . FA C T O R S I N F L U E N C I N G VA P O R I Z AT I O N...
  • Page 8: Commissioning And Operation

    6 . T H E H O T A I R G E N E R AT O R PLENTY 7. C O M M I S S I O N I N G A N D O P E R AT I O N...
  • Page 9: Temperature Setting

    If the auto off release handle is pressed the adjustment wheel of the tempera- while the PLENTY is held in the hand whatsoever for damages caused by ture safety regulator. during operation, then the set tempera- alterations to the device or fixation of ture level will be automatically retained.
  • Page 10: Filling The Filling Chamber

    8. FILLING THE FILLING CHAMBER 8. FILLING THE FILLING CHAMBER Turn the Filling Chamber Cap coun- Remove the Filling Chamber Cap with terclockwise in order to remove it from Cooling Coil and Mouthpiece from the the Filling Chamber. Filling Chamber. Always fill the Filling Chamber com- pletely with finely crushed or ground plant material.
  • Page 11 8. FILLING THE FILLING CHAMBER 8. FILLING THE FILLING CHAMBER correct wrong vapor hot air Filling Chamber only partially filled Filling Chamber only partially filled, with Liquid Pad placed on top If the Filling Chamber is only partially filled, then the vaporization material Uniform flow through the Hot air only;...
  • Page 12: Application

    Once the Hot Air Generator has reached the set temperature (the or- ange control lamp turns off, or the thermometer displays the desired temperature), the inhaling process can then begin. Heating the PLENTY Hot Air Generator...
  • Page 13: Disassembling, Cleaning And Assembling

    Paper or cotton towels may be used vapors is reduced. for manual cleaning; use alcohol (eth- The PLENTY Vaporizer is intended to anol) for metal components (Filling be used while seated. Chamber Cylinder, Screens, Cooling...
  • Page 14: Disassembling The Mouthpiece

    10. DISASSEMBLING, CLEANING AND ASSEMBLING 10. DISASSEMBLING, CLEANING AND ASSEMBLING 10.3. Disassembling the Filling The Vaporization Unit may be eas- Push the upper Screen out of the Fill- ily disassembled and reassembled Chamber Cap ing Chamber Cap from above, by us- for cleaning in a few seconds.
  • Page 15: Disassembling The Filling Chamber

    Filling Chamber Housing from above, The voltage specification is located on Filling Chamber and turn it so that the flattened position- the type label of the PLENTY Hot Air Cylinder ing surfaces are located in the intended Generator. Filling Chamber...
  • Page 16: Warranty, Liability, Repair Service

    The warranty period for the PLENTY tort, strict liability, or imposed by stat- and those warranties arising from a due to normal wear and tear or dete-...
  • Page 17 13. WARR ANT Y, LIABILIT Y, REPAIR SERVICE Repair Service this allocation of risk, and but for this allocation and limitation of liability, After the warranty period has expired, Company would not have entered into or if there are any defects which are this agreement.
  • Page 18 S TO R Z & B I C K E L G M B H & C O. K G In Grubenäcker 5-9 · 78532 Tuttlingen/Germany S TO R Z & B I C K E L A M E R I C A I N C. 1078 60th Street Suite A ·...