Digital I/O Tests; Sim Test - Nokia 616 Service Manual

Carkit phone (tfe-4/rv-1)
Hide thumbs Also See for 616:
Table of Contents

Advertisement

Nokia Customer Care

Digital I/O Tests

For this test following Workflow is necessary:
Step 1:
Start Phone by Ignition Switch on AD-2 Power adapter
Scan Product, set to local mode
Open the Digital I/O Test from the Testing drop down menu.
Step 2:
Read "Ignition", should be Active
Activate "Power Supply" option (Alt-o')
Switch off Ignition sense,
Read "Ignition", should be inactive now and no error shall occur
Switch on Ignition Sense on AD-2
Read again Ignition, should be active now
Switch on Display Power and connect an Input Device
Connected Input device should have activated Lights now (alternative mea-
sure the Voltage VIDU at Display and Input device connector by voltage meter
should be <>0V)
Deactivate "Display Power" option, Lights of the Input Device should be off
now
Activate CRM option, LED at AD-2 Power adapter should lighten
Deactivate CRM light should be off now
SIM-TEST
Test description:
SIM-card can be tested by normal Phone call or within Phoenix. This test is supported by
the SIM Test.
Open the SIM Test Menu from the Testing drop down menu.
Plug into SIM reader a functioning SIM card and press Update. (TF-4R Device has to be in
Issue 2.0 Mar/2005
Prepare Phone and Phoenix
Figure 5: Digital IO Test
Do the tests
Copyright © 2005 Nokia Corporation
Company Confidential
TFE-4/RV-1
3 - Service Software
Page 3-35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

610