Replacing Air Filter Element

Removing a pressurized air filter bowl could cause
serious injury. Depressurize air line before servicing.
Check the 5 micron air manifold filter daily and replace
element (317a, Part No. 15D909) as needed.
1. Close main air shutoff valve on air supply line and
on unit. Depressurize air line.
2. Remove filter cover (A). See F
3. Unscrew filter bowl (B).
4. Remove and replace element (317a).
5. Screw filter bowl (B) on securely. Install cover (A).
317a
B
A
TI12691a
F
. 19: Replacing Air Filter Element
IG
46
. 19.
IG
TI13069a

Wall Mount Fluid Station

Preparation
1. Follow Before Servicing, page 40.
2. Loosen the 4 screws (307), then remove the Wall
Mount Fluid Station cover (322). F