Graco ProMix 2KS Repair Manual page 39

Plural component proportioner
Hide thumbs Also See for ProMix 2KS:
Table of Contents

Advertisement

Color
Description
Green
Dose A On
Green
Dose B On
Green
Purge A On
Green
Purge B On
Green
Dump A
Green
Dump B
Red
Dose A Off
Red
Dose B Off
Red
Purge A Off
Red
Purge B Off
Natural
Solenoid Air Supply
Natural
Flow Control Air Supply
Natural
Purge Air Supply
312780K
Table 6: Tubing Chart
Starting Point
A2
A4
A6
A8
DA
DB
B1
B3
B5
B7
13
14
Use as a separate line
connected directly to the
main shop air line. Do
not connect to the unit's
main air supply or to the
air manifold (335).
Ending
Tube OD
Point
in. (mm)
A2
5/32 (4)
A4
5/32 (4)
A6
5/32 (4)
A8
5/32 (4)
DA
5/32 (4)
DB
5/32 (4)
B1
5/32 (4)
B3
5/32 (4)
B5
5/32 (4)
B7
5/32 (4)
13
1/4 (6)
14
1/4 (6)
AT
1/4 (6)
Schematic Diagrams
Tube Ref. No.
336
336
336
336
Included in optional
Dump Valve Kit
15V821 (Wall Panel)
or 15V822 (RoboMix)
337
337
337
337
334
User supplied. Con-
nects air manifold to
flow control regulator.
338
39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents