Dial Tone Detection In Pabx; Wsw04; Earth Function In Transfer Facility (Not Used.); Dual Tone Detection Frequency In Icm Recording - Brother MFC640CW Service Manual

Hide thumbs Also See for MFC640CW:
Table of Contents

Advertisement

Selectors 6 and 7: Dial tone detection in PABX (Not used.)
These selectors activate or deactivate the dial tone detection function which detects a dial tone
when a line is connected to the PABX.
Setting both of these selectors to "1" activates the dial tone detection function so that the machine
starts dialing upon detection of a dial tone when a line is connected.
Other setting combinations deactivate the dial tone detection function so that the machine starts
dialing after the specified WAIT (3.5, 5.0, or 7.0 sec.) without detection of a dial tone when a line
is connected.
Selector
No.
Earth function in transfer
1
facility (Not used.)
2
Dual tone detection frequency
in ICM recording
3
Dual tone detection
4
sensitivity in ICM recording
5
Not used.
6
Break time length for flash
|
function
8
NOTE: Selectors 1 and 5 through 8 are not applicable in those countries where no transfer facility is
supported.
NOTE: Selectors 2 through 4 are applicable to models equipped with built-in TADs.
Selector 1:

Earth function in transfer facility (Not used.)

This selector determines whether or not the earth function is added to the transfer setting menu to be
accessed by the function switch.
Selectors 2 and 3: Dual tone detection frequency in ICM recording
If the machine detects either of the frequencies set by these selectors in ICM recording, it
disconnects the line. For example, if these selectors are set to "0, 0," the machine disconnects the
line upon detection of 350 or 440 Hz.

WSW04

(TRANSFER facility setting)
Function
App. 4-5
Setting and Specifications
0: Provided
No. 2 3
0 0
: 350 and 440 Hz (A)
0 1
: 440 and 480 Hz (B)
1 0
:
480 and 620 Hz (C)
1 1
:
0: Normal
No. 6 7 8
0 0 0 : 80 ms
0 0 1 : 100 ms
0 1 0 : 110 ms
0 1 1 : 120 ms
1 0 0 : 200 ms
1: Not provided
1: High
No. 6 7 8
1 0 1 : 250 ms
1 1 0 : 500 ms
1 1 1 : 700 ms
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcp340cwMfc820cw

Table of Contents