Table of Contents

Advertisement

Selector
No.
1
Pause key setting and 2nd dial
|
tone detection
3
4
|
Detection of international tone
6
No. of 2nd dial tone detection
7
cycles
Allowable instantaneous interrupt
8
during reception of 2nd dial tone
NOTE: Selectors 4 through 8 are not applicable in those countries where no dial tone detection is
supported, e.g., U.S.A.

WSW06

(Pause key setting and 2nd dial tone detection)
Function
App. 4-8
Setting and Specifications
No.
1 2 3
0 0 0 :
No pause
0 0 1 :
3.5 sec. WAIT
0 1 0 :
7 sec. WAIT
0 1 1 :
10.5 sec. WAIT
1 0 0 :
2.5 sec. WAIT
1 1 0 :
2nd dial tone detection
only in pulse dialing (DP)
system
1 0 1 :
2nd dial tone detection
1 1 1 :
both in DP and push-button
(PB) dialing system
No.
4 5 6
0 0 0 :
50 ms
0 0 1 :
250 ms
0 1 0 :
500 ms
0 1 1 :
620 ms
1 0 0 :
800 ms
1 0 1 : 1.5 sec.
1 1 0 : 2.0 sec.
1 1 1 : 2.5 sec.
0: 1 cycle
0: 30 ms
1: 2 cycles
1: 50 ms
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: