Product Compliance; Safety Information; Box Content - Salus EP110 Installation Manual

Wireless programmable room thermostat/single channel programmable controller
Hide thumbs Also See for EP110:
Table of Contents

Advertisement

Product compliance

This product complies with the essential requirements and other relevant provisions of the following EU
Directives: 2014/30/EU, 2014/35/EU and 2011/65/EU. Please check www.saluslegal.com for the full information.

Safety Information

Use in accordance with the EU and national regulations. For indoor use only. Keep your device completely
dry. This product must be installed by a competent person and in accordance with all the EU and national
regulations.
Always isolate the AC Mains supply before installing or working on any components that
require 230 VAC 50Hz supply.

Box content

The box includes the EP110 controller, 2X screws and plugs and the Quick Guide installation manual.
EP110 Controller
Model: EP110/EP210/EP310
Installer Manual-Quick Guide
Introduction
Quick Guide Installation
A programmable controller is used to switch the heating system and/or
the hot water in your home on and off as needed. It works by controlling
the central heating and/or the hot water with programmed settings that
take effect at different times of the day.
Go to www.salus-manuals.com for the full PDF version of the manual.
Product Compliance
EU Directives: 2014/30/EU, 2014/35/EU and 2011/65/EU. Please check
www.saluslegal.com for the full information.
Safety Information
Use in accordance with the EU and national regulations.
2x screws and plugs
Input:
230V, 50Hz
Installation
Output: 3A/ switch terminal
1
EP110 Volt Free application only
Note: Please remove red link wire for this application.
Terminal
Description
N
Mains Neutral
L
Mains Live
1
Not Used
2
Not Used
3
Volt Free Connection
4
Volt Free Connection
Earth Parking
(no electrical connection)
EP110 - 230V Application Only
Terminal
Description
N
Mains Neutral
L
Mains Live
1
NC (Output)
2
Not Used
3
Switch Live (Output)
4
230V Common (via Link)
EP110 Installation Manual
Earth Parking
(no electrical connection)
2
EP210 - 230V Application
Jumper Settings
Changes to the jum
out the installation o
positions required i
These jumpers are fo
EP1
Backplate
N L 1 2 3
4
N L 1 2 3
4 5 6
E
Switch
Fe
Fully pum
System
or gravi
sy
5-2 day
Program
24h
Backplate
Memory
Disable/e
Backup
bac
* P - Fully pumped s
* G - Gravity Hot Wat
N L 1 2 3
4
N L 1 2 3
4 5 6
First Power Up
03
EP110

Hide quick links:

Advertisement

Table of Contents
loading