SCAN DSA 12 Assembly And Instruction Manual

SCAN DSA 12 Assembly And Instruction Manual

Built-in stove

Advertisement

GB
A S S E M B LY- A N D I N S T R U C T I O N S M A N U A L
Scan DSA 12
Congratulations on your new Scan built-in stove
You have purchased a product by one of Europe's leading manufacturer's of wood-burning stoves, and we are sure that you will have years of plea-
sure with your purchase. To make the best possible use of your built- in stove, it is important that you follow our advice and instructions.
Please read this Assembly- and instructions manual before you start to assemble your built-in stove.
Product registration number
Please indicate the product registration number at any enquiry
S C A N A / S - D K- 5 4 9 2 V I S S E N B J E R G

Advertisement

Table of Contents
loading

Summary of Contents for SCAN DSA 12

  • Page 1 A S S E M B LY- A N D I N S T R U C T I O N S M A N U A L Scan DSA 12 Congratulations on your new Scan built-in stove You have purchased a product by one of Europe’s leading manufacturer’s of wood-burning stoves, and we are sure that you will have years of plea- sure with your purchase.
  • Page 2: Table Of Contents

    C O N T E N T S Table of contents Technical data ....................3 Installation Safety Technical dimensions and data Dimension sketch for Scan DSA 12 Type plate Additional accessories Product registration number Assembly ....................... 6 Dismantling Load-bearing foundation...
  • Page 3: Technical Data

    To ensure best-possible functionality and safety for your installation, Connecting piece external diameter: 179 mm we advise you to call a professional fitter. Our Scan Dealer will be able to recommend a qualified fitter in your area. For information on Scan Approval type: Intermittent fuelling Dealers, please go to www.scan.dk.
  • Page 4 T E C H N I C A L DATA Dimension sketch for Scan DSA 12 274** Height to the begin- ning of the flue pipe at top outlet Centre for inlet of external combustion air bottom Scan DSA 12 Målskitse Scan DSA 12...
  • Page 5: Type Plate

    Product registration number Type plate All wood-burning stoves are provided with a product registration All Scan wood-burning stoves are fitted with a type plate, that speci- number. fies the approval standards and the distance to flammable materials. Please make a note of this number on the front page as you will always have to state it when contacting your dealer or Scan A/S.
  • Page 6: Assembly

    A S S E M B LY Dismantling Removing the trims: The Scan DSA 12 is supplied attached to a pallet. It is recommended Remove the flange nuts and lift off the trims. that you remove both doors and trims before unscrewing the stove from the pallet.
  • Page 7: Load-Bearing Foundation

    If you have chosen to install the Scan DSA 12 on flammable material, it Choosing the wrong length or diameter of steel chimney could is a legal requirement that steel floor plates be used on both sides of impair functionality.
  • Page 8: Adjustable Supporting Legs

    When the supporting legs are in their highest position, the stove will be 1388.6 mm tall. When they are at the bottom, the stove will The Scan DSA 12 is supplied with adjustable supporting legs. These be 989 mm tall.
  • Page 9 400 mm. Area for convection air in: 350 cm 2 Minimum 300mm distance to flammable materials Non-flammable plate Flammable material Supporting of stove on non-flammable side pieces Indbygning i forbindelse med brændbar væg 90085016 Scan DSA 12 TG.NR: NAVN: EMNE:...
  • Page 10 A S S E M B LY Flammable material 200 mm mineral wool Non-flammable plate or covering Flammable material Indbygning i forbindelse med brændbart loft Scan DSA 12 90085015 NAVN: EMNE: TG.NR: 01-02-10 DATO: SIGN: MATERIALE: VÆGT:...
  • Page 11: Door Lock

    • Minimum Ø100 mm ventilation pipe, maximum length: 6 m with a maximum of one bend External combustion air can be connected to the connection piece underneath the combustion chamber. Scan DSA 12 Låsning af låge NAVN: EMNE: TG.NR: 90085021...
  • Page 12: Dimension Sketch For Scan Dsa

    F I T T I N G O F A C C E S S O R I E S Fitting the convection adaptors Scan DSA 12 Tilbehør - Konvektionsstudse 90085006 NAVN: EMNE: TG.NR: 09-06-2011 MATERIALE: VÆGT: DATO: SIGN: DIMENSION: AREAL: Krog Iversen &...
  • Page 13: Instruction For Use

    Pin supporting the baffle plate Adjustment of air supply, primary and secondary damper Primary air Secondary air 0% - 100% Primær og sekundær luftregulering Scan DSA 12 90085007 NAVN: EMNE: TG.NR: Brændkammer, spjæld og askeskuffe Scan DSA 12 90085005 NAVN: EMNE: TG.NR:...
  • Page 14: Instructions For Heating

    We recommend the use of fire starters, or similar products, which are setting the primary airflow to full power. Running the stove at too available from your Scan dealer. Using fire starters helps to light the low a temperature and with too little primary air can lead to defla- wood quicker, and keeps the burning process clean.
  • Page 15: Handling Fuel

    I N S T R U C T I O N S F O R H E AT I N G Handling fuels The draft in the chimney is caused by the difference in temperatures inside and outside the chimney. The higher the temperature differen- ce is, the better the draft in the chimney will be.
  • Page 16: Maintenance

    If the topcoat is damaged, you can purchase a repair spray from your pipe, we recommend first removing the smoke deflector plates. authorised Scan dealer. As slight differences in colour are possible, spray a larger area to achieve a natural transition for best results.
  • Page 17 M A I N T E N A N C E Positioning the baffle plates and combustion chamber sides Upper baffle plates Upper combustion chamber sides Lower baffle plate Lower combustion chamber sides Røgvenderplader, snittegning Scan DSA 12 90085023 NAVN: EMNE: TG.NR: 03-02-10 MATERIALE: VÆGT:...
  • Page 18: Troubleshooting

    Scan dealer with a warranty claim. • Check if the flue pipe/chimney are blocked The warranty covers all parts which in the opinion of Scan A/S require • Is the chimney the right height for its surroundings? repair or replacement due to manufacturing or construction error •...
  • Page 20 Version Scan A/S - DK-5492 Vissenbjerg GB 90085500-6 29.02.2016...