Fuse Size - Hitachi WJ-0001S User Manual

Wj200 series solar water pump inverter system
Table of Contents

Advertisement

Fuse Size

The unit shall be connected with a Listed Cartridge Nonrenewable fuse or Inverse
time circuit breaker, rated 600 Vac with the current ratings as shown in the table
below
Model No.
WJ-0001S
WJ-0002S
WJ-0004S
WJ-0007S
WJ-0015S
WJ-0022S
WJ-0004H
WJ-0007H
WJ-0015H
WJ-0022H
WJ-0030H
WJ-0040H
WJ-0055H
WJ-0075H
WJ-0110H
WJ-0150H
Fuse
Type
Rating(Maximum A)
Class
10 A, AIC 200 kA
J
Class
10 A, AIC 200 kA
J
Class
10 A, AIC 200 kA
J
Class
15 A, AIC 200 kA
J
Class
15 A, AIC 200 kA
J
Class
20 A, AIC 200 kA
J
Class
10 A, AIC 200 kA
J
Class
10 A, AIC 200 kA
J
Class
10 A, AIC 200 kA
J
Class
10 A, AIC 200 kA
J
Class
15 A, AIC 200 kA
J
Class
15 A, AIC 200 kA
J
Class
30 A, AIC 200 kA
J
Class
30 A, AIC 200 kA
J
Class
50 A, AIC 200 kA
J
Class
50 A, AIC 200 kA
J
Inverse Time
Type E CMC
Circuit Breaker
Rating (Maximum
A)
30A
20A
480V,40A or
40A
Ii
MMS-32H,
240V,40A
MMS-32H,
MMS-63H,
480V,52A