Phase 400V Class - Hitachi WJ-0001S User Manual

Wj200 series solar water pump inverter system
Table of Contents

Advertisement

Standard Specifications
1-phase 200V class
Models WJ200-
kW
Applicable motor size *
1
HP
200V
Rated capacity (kVA)
240V
Rated input voltage (V)
Input
Rating
Rated input current (A)
Rated output voltage (V) *
2
Output
Rating
Rated output current (A)
Minimum value of resistor (Ω)
Weight
3-phase 200V class
Models WJ200-
kW
Applicable motor size *
1
HP
200V
Rated capacity (kVA)
240V
Rated input voltage (V)
Input
Rating
Rated input current (A)
2
Rated output voltage (V) *
Output
Rating
Rated output current (A)
Minimum value of resistor (Ω)
Weight

3-phase 400V class

Models WJ200-
kW
Applicable motor size *
1
HP
200V
Rated capacity (kVA)
240V
Rated input voltage (V)
Input
Rating
Rated input current (A)
Rated output voltage (V) *
2
Output
Rating
Rated output current (A)
Minimum value of resistor (Ω)
Weight
001SF
002SF
VT
0.2
0.4
CT
0.1
0.2
VT
1/4
1/2
CT
1/8
1/4
VT
0.4
0.6
CT
0.2
0.5
VT
0.4
0.7
CT
0.3
0.6
VT
2.0
3.6
CT
1.3
3.0
VT
1.2
1.9
CT
1.0
1.6
100
100
kg
1.0
1.0
lb
2.2
2.2
001LF
002LF
004LF
VT
0.2
0.4
0.75
CT
0.1
0.2
0.4
VT
1 / 4
1 / 2
1
CT
1 / 8
1 / 4
1 / 2
VT
0.4
0.6
1.2
CT
0.2
0.5
1.0
VT
0.4
0.7
1.4
CT
0.3
0.6
1.2
VT
1.2
1.9
3.9
CT
1.0
1.6
3.3
VT
1.2
1.9
3.5
CT
1.0
1.6
3.0
100
100
100
kg
1.0
1.0
1.1
lb
2.2
2.2
2.4
004HF
007HF
015HF
VT
0.75
1.5
2.2
CT
0.4
0.75
1.5
VT
1
2
3
CT
1/2
1
2
VT
1.3
2.6
3.5
CT
1.1
2.2
3.1
VT
1.7
3.4
4.4
CT
1.4
2.8
3.9
VT
2.1
4.3
5.9
CT
1.8
3.6
5.2
VT
2.1
4.1
5.4
CT
1.8
3.4
4.8
180
180
180
kg
1.5
1.6
1.8
lb
3.3
3.5
4.0
004SF
007SF
0.55
1.1
0.4
0.75
3/4
1.5
1/2
1
1.2
2.0
1.0
1.7
1.4
2.4
1.2
2.0
1-phase: 200V-15% to 240V +10%, 50 / 60Hz ±5%
7.3
13.8
6.3
11.5
3-phase: 200 to 240V (proportional to input voltage)
3.5
6.0
3.0
5.0
100
50
1.1
1.6
2.4
3.5
007LF
015LF
022LF
037LF
1.1
2.2
3.0
5.5
0.75
1.5
2.2
3.7
1.5
3
4
7.5
1
2
3
5
2.0
3.3
4.1
6.7
1.7
2.7
3.8
6.0
2.4
3.9
4.9
8.1
2.0
3.3
4.5
7.2
3-phase: 200V-15% to 240V +10%, 50 / 60Hz ±5%
7.2
10.8
13.9
23.0
6.0
9.0
12.7
20.5
3-phase: 200 to 240V (proportional to input voltage)
6.0
9.6
12.0
19.6
5.0
8.0
11.0
17.5
50
50
35
35
1.2
1.6
1.8
2.0
2.6
3.5
4.0
4.4
022HF
030HF
040HF
3.0
4.0
5.5
2.2
3.0
4.0
4
5
7.5
3
4
5
4.5
5.7
7.3
3.6
4.7
6.0
5.7
7.3
9.2
4.5
5.9
7.6
3-phase: 380V-15% to 480V +10%, 50 / 60Hz ±5%
8.1
9.4
13.3
6.5
7.7
11.0
3-phase: 380 to 480V (proportional to input voltage)
6.9
8.8
11.1
5.5
7.2
9.2
100
100
100
1.9
1.9
2.1
4.2
4.2
4.6
015SF
022SF
2.2
3.0
1.5
2.2
3
4
2
3
3.3
4.1
2.7
3.8
3.9
4.9
3.3
4.5
20.2
24.0
16.8
22.0
9.6
12.0
8.0
11.0
50
35
1.8
1.8
4.0
4.0
055LF
075LF
110LF
7.5
11
15
5.5
7.5
11
10
15
20
7.5
10
15
10.3
13.8
19.3
8.6
11.4
16.2
12.4
16.6
23.2
10.3
13.7
19.5
37.0
48.0
68.0
30.8
39.6
57.1
30.0
40.0
56.0
25.0
33.0
47.0
20
17
17
3.3
3.4
5.1
7.3
7.5
11.2
055HF
075HF
110HF
7.5
11
15
5.5
7.5
11
10
15
20
7.5
10
15
11.5
15.1
20.4
9.7
11.8
15.7
14.5
19.1
25.7
12.3
14.9
19.9
20.0
24.0
38.0
16.9
18.8
29.4
17.5
23.0
31.0
14.8
18.0
24.0
70
70
70
3.5
3.5
4.7
7.7
7.7
10.4
Ii
150LF
18.5
15
25
20
23.9
20.7
28.6
24.9
72.0
62.6
69.0
60.0
10
7.4
16.3
150HF
18.5
15
25
20
25.0
20.4
31.5
25.7
44.0
35.9
38.0
31.0
35
5.2
11.5

Advertisement

Table of Contents
loading