Hitachi WJ-0001S User Manual page 37

Wj200 series solar water pump inverter system
Table of Contents

Advertisement

E61
Option error (duplicated
MACID)
E62
Option error (External trip)
E63
Option error
to
E68
E69
Option error (inverter
communication error)
E80
Encoder disconnection
E81
Excessive speed
E83
Positioning range error
output and display the error code shown on the
right. (The inverter will trip according to the
settings of "p45" and "P048".)
If two or more devices having the same MAC ID
are detected in the same network, the inverter
will display the error code shown on the right.
If the Force Fault/Trip bit of Attribute 17 in the
Instance 1 of the Control Supervisory object is
set to "1", the inverter will shut off its output and
display the error code shown on the right.
The inverter detects errors in the option board
mounted in the optional slot. For details, refer to
the instruction manual for the mounted option
board.
If timeout occurs during the communication
between the inverter and DeviceNet option
board, the inverter will shut off its output and
display the error code shown on the right.
If the encoder wiring is disconnected, an encoder
connection error is detected, the encoder fails, or
an encoder that does not support line driver
output is used, the inverter will shut off its output
and display the error code shown on the right.
If the motor speed rises to "maximum frequency
(A004) x over-speed error detection level (P026)"
or more, the inverter will shut off its output and
display the error code shown on the right.
If current position exceeds the position range
(P072-P073), the inverter will shut off its output
and display the error code.