2.5.1 DIAGNOSTIC

Disturbance free precision power for supporting the battery during the vehicle
electric system diagnostic operations (function used mainly in workshops).
FUNCTION SELECTION
MODE
The set voltage is present on the charge clamps when connected to the
battery.
NOTE. The battery must not be disconnected from the vehicle (so as not
to lose the setup settings) and must have a minimal voltage of 5V to
guarantee the correct functioning of the process.
ATTENTION! Check the maximum permissible voltage on the vehicle
manufacturer's technical specifications to prevent damage to the on-board
electronics and the battery.
Customising VOLTAGE and CURRENT
VOLTAGE
– press and hold simultaneously the "BATTERY VOLTAGE" (fig.A.21) and "MODE"
buttons (fig. A.22) for 3 seconds;
– use the same buttons to select (decrease using the "BATTERY VOLTAGE" button
and increase using the "FUNCTION" button) the desired voltage value between
6V-7.5V, 12V-15V, 24V-30V respectively for 6V, 12V, 24V batteries; the factory
default voltage value is respectively 6.8V, 13.6V, 27.2V.
The set voltage mode will be exited automatically after a 3" time-out.
VOLTAGE ADJUSTMENT – EXAMPLE
BATTERY
VOLTAGE
DISPLAY
22
DISPLAY
CHARGE
RATE
3
BEEP
13.3V
13.2V
13.1V
. . . . .
. . . . .
13.7V
13.6V
13.5V