ATTENTION! Pay special attention to the type of battery being equalized
(WET, GEL, AGM, PbCa): check the maximum allowed voltage to avoid
FUNCTION SELECTION
damaging the same.
MODE
Customising the VOLTAGE
To customise the equalization voltage value simultaneously press and hold the
"BATTERY VOLTAGE" (fig. A.21) and "MODE" (fig. A.22) buttons for 3 seconds,
then use the same buttons to select (decrease using the "BATTERYVOLTAGE"
button and increase using the "MODE" button), the desired voltage value between
6V-8.0V, 12V-16V, 24V-32V respectively for 6V, 12V, 24V batteries.
The factory default voltage value is respectively 6.8V, 13.6V, 27.2V.
The set voltage mode will be exited automatically after a 3" time-out.
VOLTAGE ADJUSTMENT – EXAMPLE
BATTERY VOLTAGE
DISPLAY
Procedure
– press the "MODE" button (fig. A.22) to select this function (fig. A.9);
– press the "BATTERY VOLTAGE" button (fig. A.21) to select the battery voltage
(fig. A.1);
– connect the clamps to the battery terminals;
– the equalization process will run automatically indicating the voltage value on
the display (fig.A.2), along with the current (fig. A.4) output. On completing the
process, the word "End" will appear on the display (fig. A.2).
END OF PROCESS – EXAMPLE
BEEP
20
ADVANCED MENU SELECTION
DISPLAY
MODE
3"
BEEP
13.3V
13.2V
13.1V
. . . . .
. . . . .
13.7V
13.6V
13.5V
Info