Electrolux Compass Pro Programming And Configuration Manual page 26

Up to 55 programs
Table of Contents

Advertisement

26
4.7.2.6
CHANGE TIME STEP
Set the step time that is displayed in the user interface when selecting time in a time program.
If the time is set to 5 minutes, when selecting time in the user interface, the time will be displayed with 5 minutes inter-
vals. 5, 10, 15 etc.
The time is set in minutes and seconds.
The pre-set value is 5 minutes.
If the value is set to 0 the function is disabled.
4.7.2.7
POWER CTRL HEAT
Set if the power priority function for heating shall be engaged or not.
YES = Power priority engaged
NO = Power priority not engaged
4.7.2.8
ECOPOWER STARTUP TIME
Set the time that shall pass before the EcoPower function is enabled.
The time is set in seconds.
The pre-set value is 90 seconds.
Recommended range: 1–15 minutes. Values set out of range may deteriorate the performance of the machine.
If the value is set to 0 the EcoPower function is disabled in the machine.
4.7.2.9
ECOPOWER TEMP. LOW
Set the temperature for ECOPOWER TEMP. LOW function.
The pre-set value is 55°C.
4.7.2.10 ECOPOWER TEMP. HIGH
Set the temperature for ECOPOWER TEMP. HIGH function.
If the outlet temperature is above this temperature after ECOPOWER STARTUP TIME, EcoPower is disabled.
Also used to calculate "adjust for small loads" if the temperature is between ECOPOWER TEMP. LOW and ECOPOWER
TEMP. HIGH.
The pre-set value is 65°C.
4.7.2.11 ECOPOWER EXTRA TIME
Set the extra time before the temperature is lowered to ECOPOWER ENABLE TEMP. after it has reached "high temp."
The time is set in seconds.
The pre-set value is 600 seconds.
Recommended range: 5–15 minutes. Values set out of range may deteriorate the performance of the machine.
4.7.2.12 ECOPOWER ENABLE TEMP.
Enable temperature for EcoPower. (Temperature and extra drying time (+ "adjust for small loads") is fulfilled.
The pre-set value is 45°C.
Recommended range: 40–50°C. Values set out of range may deteriorate the performance of the machine.
4.7.2.13 TIMEOUT VACUUM
Set the time that shall pass before the error code "TIMEOUT VACUUM" is activated.
The time is set in seconds.
The pre-set value is 15 seconds.
4.7.2.14 RESTORE VAC. ERR. W/DOOR
Decide if the vacuum error codes shall be reset when opening the door or not. (Valid at program start).
YES = It is possible to reset vacuum error codes by opening the door.
NO = Vacuum error codes are handled like all other error codes and will not be reset by opening the door.
Programming and Configuration Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents