ENGLISH
1) Only cold water must be supplied to the appliances.
2) If the mains water pressure exceeds 6 bar, a pressure reducer must be installed to regulate the
outlet pressure to a maximum of 6 bar.
3) Connect the drain hose to the tray, avoiding sharp bends and keeping a sufficient slope for
regular flow of the drain water.
4) Connect the 3/8" hose to the mains outlet and then to the water softener and to the appliance.
N.B. A water softener is indispensable for correct appliance operation, best coffee in the cup
and long life of the components, since it removes scale and residues from the water that would
otherwise shorten their life.
The company is relieved of all and any liability in the event of failure to comply with
the above instructions.
Open the tap and let water flow through the deconcentrator to clear dirt off the circuit before plug-
ging the hose into the pump.
Water connection
36