7 CONNECTIONS

IMPORTANT: the machine must
be connected by a specialised
authorised technician.
7.1

WATER CONNECTION

Drain
Near the machine there must be a drain (1) with
siphon.
Connect the end of the drain hose (2) to the fitting
(3) on the drain tray and fix with the hose clips.
Connect the other end of the drain hose (2) to the
drain (1) prepared previously.
EN
The machine must be connected
to a mains water supply
providing appropriately softened
drinking water with a maximum
hardness of 3.5/5 French degrees
(60/85 ppm). Make sure the
supply pressure does not exceed
6 bars (0.6 MPa). If the pressure
is greater, install a pressure
reducer.
Filling

Filling (for version with built-in pump)

- Connect the intake hose (7) to a water softer (8),
interposing the water purifying filter (9) supplied;
- Install a splitter tap (10) before the water
softener (8), to separate the machine from the
mains water supply.
3
2
Connections
1

Filling (for version with external pump)

On request, the pump may be installed externally,
rather than internally, proceeding as follows:
Position the pump away from
heat sources and water jets on
a horizontal surface adequately
sized for the weight of the pump
itself.
-
The pump (12) must be positioned below the
machine no further than 100 cm away, leaving
at least 5 cm between the pump and the outer
panels to avoid vibration transmission and
guarantee correct air circulation.
- Connect the hose (7) coming out of the machine
to the delivery coupling on the pump (12).
- Connect one end of the hose (11) provided to
the intake coupling on the pump and the other
end to a water softener (8), interposing the
water purifying filter (9).
- Install a splitter tap (10) before the water
softener (8), to separate the machine from the
mains water supply.
- Connect the connector (13) on the pump to the
corresponding connector (14) on the machine.