9 Notification Messages

During boot-up and normal operation, the Vector constantly checks its status and settings, and the status of any
connected accessories. If an issue is detected, the Vector will display a message in the OSD notification area
either temporarily or until the issue is resolved, depending on the importance of the message.
The table below describes these messages, and what they mean. Note that it is unlikely you will ever see most
of these messages.
Onscreen Notification
2nd Aileron Input not Detectd
2nd Ailrn Issue:Rerun Wizard!
2nd Elevatr Input not Detectd
2nd Elvtr Issue:Rerun Wizard!
2nd Rudd Issue: Rerun
Wizard!
2nd Rudder Input not Detected
Aileron Issue: Rerun Wizard!
Ailron or Elevatr undetected!
Airframe Not Set
Airframe Type Change Detected
Altimeter not detected!
Alt Hold Failing: Vib too hi!
Alt Hold Reset: Vib too high!
Alt Hold Failure: Vib too hi!
You configured the Vector to receive a mixed 2
your transmitter, but that signal is not detected. Check your wiring and
receiver settings.
You configured the Vector to receive a mixed 2
your transmitter, but that signal was not correctly detected when you
ran the Receiver Analysis Wizard. Please check correct operation of the
2
output from your transmitter, and rerun the wizard.
nd
You configured the Vector to receive a mixed 2
your transmitter, but that signal is not detected. Check your wiring and
receiver settings.
You configured the Vector to receive a mixed 2
your transmitter, but that signal was not correctly detected when you
ran the Receiver Analysis Wizard. Please check correct operation of the
2
output from your transmitter, and rerun the wizard.
nd
You configured the Vector to receive a mixed 2
your transmitter, but that signal was not correctly detected when you
ran the Receiver Analysis Wizard. Please check correct operation of the
2
output from your transmitter, and rerun the wizard.
nd
You configured the Vector to receive a mixed 2
your transmitter, but that signal is not detected. Check your wiring and
receiver settings.
When you ran the Receiver Analysis Wizard, the Vector did not detect
correct movement of the aileron input. Check your wiring and settings
and run the wizard again.
The Vector did not detect your aileron and/or elevator signal during
boot. Either these wires are not connected correctly, or your receiver or
transmitter was not powered during boot.
You have not yet set the airframe type, which is required to use the
Vector's flight controller.
This message will appear, along with an image of the presently selected
airframe type, when you first boot the Vector after changing the
airframe type. You must OK the airframe type by clicking the mode
switch once while this message is displayed on the screen.
If you repeatedly see this message, DON'T FLY and contact support.
The Vector has detected that there is too much vibration for altitude
hold to work correctly.
The Vector has reset the altitude hold logic, due to continued
excessive vibration.
The altitude hold function has failed, due to continued excessive
vibration.
Meaning of Message
aileron signal from
nd
aileron signal from
nd
elevator signal from
nd
elevator signal from
nd
rudder signal from
nd
rudder signal from
nd