Eagle Tree Systems Vector User Manual page 75

Vector multirotor/fixed wing flight controller plus osd
Table of Contents

Advertisement

7.1.2.3 The Gauge/Swatch Setup Menu
This menu lets you set up the colors and thresholds for a gauge or swatch readout.
Readout Name: This item indicates the readout being changed.
Number of Colors in Gauge: This item lets you select the number of
colors that will be used for the gauge or swatch. The range is from 2
to 5. Here are the colors that will display if you select 5 colors:
Green (indicates the best value of the readout)
Blue
Yellow
Magenta (purple)
Red (indicates the worst value of the readout)
If you select 4 colors, green, blue, yellow and red are used. If you select 3 colors, green, yellow and red are
used. If you select 2 colors, only green and red are used.
Gauge/Swatch BEST Value: Here, you enter numeric value of the readout that you want to always display the
green color. If a lower number is better for the readout, such as with altitude, you would enter the lowest
value here. If a higher number is better, such as with voltages, you would enter the highest number here.
Please see the examples at right. For the "Transmitter Voltage"
readout, the best value is set to 12.60 and the worst is 10.80. The
gauge will be green and show full at 12.60V or higher, and will show
empty and be red at 10.80V or lower.
For the "Barometric Altitude" readout, the best value is set to 0, and
the worst value is set to 400. The gauge will be green and show empty
at 0 or lower, and will show full and be red at 400 or higher.
Until you enter the WORST value below, and autofill the thresholds, a warning about the thresholds
being incorrect will appear at the bottom of the menu. This is normal.
Color Threshold 1, Color Threshold 2, Color Threshold 3,
Color Threshold 4: The color thresholds let you set the values for the readouts where the color changes will
occur. The simplest way to set these up is to set up the best and worst values, and select "Autofill Thresholds"
below. This will divide the thresholds equally between the best and worst values. Or, you can manually
change them if you want a different distribution.
Gauge/Swatch WORST Value: Here, you enter numeric value of the readout that you want to always display
the red color. If a lower number is worse for the readout, such as with voltage, you would enter the lowest
value here. If a higher number is worse, such as with altitude, you would enter the highest number here.
Autofill Thresholds!: Select this item to autofill the color thresholds as described above.
7.1.2.4 Special note about the Motor Voltage (Pack Voltage) Readout
For the Motor Voltage readout, the values entered for thresholds need to be per-cell voltages (i.e., 4.2), rather
than overall pack voltages.
between packs of different cell counts, without needing to reset the pack voltage swatch settings each time.
The Vector automatically detects the cell count for your pack, so you can switch
USER GUIDE
75

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Eagle Tree Systems Vector

Table of Contents