Encoder Test - Yamaha O1V 96 Service Manual

Digital mixing console
Table of Contents

Advertisement

01V96
• Move all of the FADERs to the set
Checking procedures
Select the item to start the check. (Check item 1 or
check item 5)
When starting the check from check item 5, push
the [
] cursor key once and move check item 5.
Starting from check item 1
q Press the [ENTER] key.
w Move all of the FADERs up.
e Manually move all of the FADERs all the way up.
r Press the [ENTER] key.
t OK is displayed. Move all of the FADERs down.
y Manually move all of the FADERs all the way down.
u Press the [ENTER] key.
i The FADERs are checked if they can automatically
move. (Check items 3 to 7)
o The judgment result is displayed.
Starting from check item 5
q Press the [ENTER] key.
w The FADERs are checked if they can
automatically move. (Check items 5 to 7)
e The judgment result is displayed.
Example of execution screen
--- FADER Move ---
NG
1 FADER Up Position
OK 2 FADER Down Position
OK 3 FADER Up
NG 4 FADER Down
OK 5 FADER Position1
OK 6 FADER Position2
OK 7 FADER Position3
[ENTER] key to Start
FADER Up
OK:
1
OK
NG
EXIT ([DEC] Key->[ENTER] Key)
1) Explanation of the automatic judgment display of
the FADER Up/Down positions
"NG: CH 8, 940, (950...1023)"
940: Stop position detected using the built-in A/D
(displayed in 1024 resolution)
(950...1023): True value when the FADER Reads
2) Explanation of the automatic judgment display of
the FADER Up/Down
"NG: CH 1, 990, (960...1020), 950"
990: Specified stop value (displayed in 1024
resolution)
94
Downloaded from
www.Manualslib.com
positions (three positions) and the
positions are checked and whether or not
the values are correct is automatically
judged using the built-in A/D.
the stop position using the built-in
A/D (displayed in 1024 resolution)
manuals search engine
(960...1020): Certified range when the FADER
detects the stop position using the
built-in A/D (displayed in 1024
resolution)
950: True value when the FADER Reads the stop
position using the built-in A/D (displayed in
1024 resolution)
3) Explanation of the automatic judgment display of
the FADER positions 1 to 3
"CH_Pos 207, 862, (792...932)"
207: Specified stop value (displayed in 256
resolution)
862: Stop position detected using the built-in A/
D (displayed in 1024 resolution)
(792...932): Certified range when the FADER
detects the stop position using the
built-in A/D (displayed in 1024
resolution)
"NG 02 (761)"
NG 02: CH2 FADER is NG.
(761): True value when the FADER Reads the
stop position using the built-in A/D
(displayed in 1024 resolution)

1-28. ENCODER test

Contents:
Check the rotation response of the
Encoder.
When the Encoder rotates clockwise, the
">" mark on the left side moves to the right.
The ">" mark changes to the "<" mark
when it reaches the right side. Then, when
the Encoder rotates counterclockwise, the
"<" mark moves to the left. When the "<"
mark reaches the left side, the Encoder is
OK.
The Encoder rotates slowly.
Example of execution screen
--- ENCODER ---
OK
PAN
OK Q
OK FREQUENCY
OK GAIN
OK WHEEL
OK ST IN 1/3
OK ST IN 2/4
CCW ------>---------- CW
If the judgment is OK,
the test continues with
the check of the next
channel automatically.
If the judgment is not
OK, press the [DEC]
key to move to the next
check.
When the Encoder
moves in the specified
direction, the bar
moves accordingly.
">" indicates CW
(clockwise) rotation.
"<" indicates CCW
(counterclockwise)
rotation.

Advertisement