Parameter Change (Function Call Event: Effect ) - Yamaha O1V 96 Service Manual

Digital mixing console
Table of Contents

Advertisement

01V96

2.8.3.26 Parameter change (Function call Event: Effect )

Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches the
device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the corresponding effect's function activates (depending
on the effect type).
STATUS
11110000 F0
ID No.
01000011 43
SUB STATUS 0001nnnn 1n
GROUP ID
00111110 3E
MODEL ID
01111111 7F
ADDRESS
00010010 12
0000ffff 0f
00000000 00
0ppppppp pp
DATA
00000000 00
0eeeeeee ee
EOX
11110111 F7
function
Freeze Play button
Freeze Record button
• This does not activate when the effect type is different.
2.8.3.27 Parameter change
When scene memory sort is executed on the 01V96, the memory sort table will
be transmitted to Studio Manager.
Studio Manager will sort the memories according to this data.
If Studio Manager performs a scene memory sort, it will transmit this data to
the 01V96.
STATUS
11110000 F0
ID No.
01000011 43
SUB STATUS 0001nnnn 1n
GROUP ID
00111110 3E
MODEL ID
00001101 0D
ADDRESS
00010011 13
0000ffff 0f
DATA
0ddddddd ds
:
0ddddddd de
EOX
11110111 F7
8-7 conversion is performed on the data area in the same way as for bulk.
2.8.3.28 Parameter request
When the 01V96 receives this data, it will transmit Sort Table Data.
STATUS
11110000 F0
ID No.
01000011 43
SUB STATUS 0011nnnn 3n
GROUP ID
00111110 3E
MODEL ID
00001101 0D
ADDRESS
00010011 13
0000ffff 0f
EOX
11110111 F7
132
Downloaded from
www.Manualslib.com
System exclusive message
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
Universal
Function call Effect Event
function
Release:0, Press:1
Effect number (0:Effect1 - 3:Effect4)
End of exclusive
channel
0x00
0:Effect1-3:Effect4
0x01
0:Effect1-3:Effect4
(Sort Table)
System exclusive message
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
01V96
Library sort table
Library type
Data
:
Data
End of exclusive
(Sort Table)
System exclusive message
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
01V96
Library sort table
Library type
End of exclusive
manuals search engine
2.8.3.29 Parameter change
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches the
device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the same processing that is executed when the key speci-
fied by Address is pressed (released).
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
01V96
MODEL ID
00001101 0D
Key remote
ADDRESS
00100000 20
Key address H
0kkkkkkk kk
0kkkkkkk kk
Key address M
Key address L
0kkkkkkk kk
Release:0, Press:1
DATA
0ppppppp pp
End of exclusive
EOX
11110111 F7
2.8.3.30 Parameter change
When transmission is enabled by receiving a Request of Remote meter, the
specified meter information is transmitted every 50msec for 10 seconds. When
you want to transmit meter information continuously, a Request must be trans-
mitted continuously within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission has been enabled by a Request, the parameter specified by
Address will be transmitted on the [Rx CH] channel at 50 msec intervals for a
duration of 10 seconds.
Transmission will be disabled if the power is turned off and on again, or if the
PORT setting is changed.
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
GROUP ID
00111110 3E
MODEL ID (digital mixer)
01V96
MODEL ID
00001101 0D
Remote meter
ADDRESS
00100001 21
0mmmmmmm mm
ADDRESS UL
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0mmmmmmm mm
Data1 H
DATA
0ddddddd dd
Data1 L
0ddddddd dd
:
:
End of exclusive
EOX
11110111 F7
* Meter data uses the unmodified DECAY value of the DSP. The inter-
pretation of the data will depend on the parameter.
(Key remote)
(Remote Meter)

Advertisement

Table of Contents
loading

Table of Contents