Fault Finding - Triton T300si Installation And Operating Instructions Manual

Wireless remote electric shower
Table of Contents

Advertisement

Problem/symptom
5 Cold indicator
light on and low
pressure indicator
light flashing.
6 Temperature
varies from
normal to cold
intermittently
during showering.
7 Pressure relief
device has operated
(water ejected from
PRD tube).
8. Low pressure
indicator light
flashing every 4
seconds.
9. Power on
indicator flashes and
unit switches itself
off.
T300si wireless remote electric shower

faulT finDinG

Cause
5.1 Purge pin not placed
correctly.
5.2 Low water pressure.
6.1 Water pressure
dropped below minimum
required (indicator
flashing).
7.1 Blocked showerhead.
7.2 Twisted/blocked
flexible shower hose.
7.3 Showerhead
not removed while
commissioning.
8.1 Batteries running
low.
9.1 Interference with
wireless signal.
action/cure
5.1.1 Isolate the electricity supply. Remove
remote pack cover and place purge pin on one pin
only.
5.2.1 Wait until the water pressure resumes
to normal (flashing low pressure indicator
extinguishes).
5.2.2 Check if stop taps are fully open. Check if
blockage in supply pipe.
6.1.1 Wait until the water pressure resumes
to normal (flashing low pressure indicator
extinguishes).
7.1.1 Clean or replace blocked sprayplate or
cartridge and then fit a new PRD.
7.2.1 Check for free passage through hose.
Replace hose if necessary and then fit new PRD.
7.3.1 Fit new PRD. Commission unit with
showerhead removed.
8.1.1 Replace batteries.
9.1.1 Reassociate the control panel to the remote
pack.