Fault Finding - Triton AS2000 SR Installation And Operating Instructions Manual

Thermostatic power shower
Table of Contents

Advertisement

IMPORTANT: Switch OFF the electricity at the mains supply and remove the correct
circuit fuse before attempting any fault finding inside the unit.
Any maintenance or repair to the shower must be carried out by a suitably competent
person.
In the unlikely event of a fault occurring please contact Triton Customer service.
DO NOT remove the shower from the installation.
Symptom
Cause
1 Water too hot.
1.1 Not enough cold water
flowing through shower.
1.2 Increase in the ambient
cold water temperature.
1.3 Cold inlet filter blocked
or check valve sticking.
1.4 Cold water supply
blocked or cut off.
2 Water too cold.
2.1 Not enough hot water
flowing through shower.
2.2 Decrease in ambient
cold water temperature.
2.3 No hot water in the
storage cylinder.
2.4 Hot inlet filter blocked
or check valve sticking.
2.5 Hot water supply
blocked or otherwise cut off.
3 Pump does not
3.1 Interrupted power
operate.
supply.
3.2 Electrical malfunction.
3.3 Motor overheated.
3.4 Start/stop switch not
connected.
Power Shower

FAULT FINDING

Action/Cure
1.1.1 Turn the temperature control clockwise.
1.2.1 Turn the temperature control clockwise.
1.3.1 Remove filter and clean. If problem is with
check valve, contact Customer Service.
1.4.1 Isolate shower and consult a competent
plumber or contact Customer Service.
2.1.1 Turn temperature control anti-clockwise.
2.2.1 Turn temperature control anti-clockwise.
2.3.1 Turn shower off and wait for hot water
cylinder to reheat.
2.4.1 Remove filter and clean. If problem is with
check valve, contact Customer Service.
2.5.1 Turn shower off. Consult a competent
plumber or contact Customer Service.
3.1.1 Blown fuse. Check supply. Renew fuse. If it
fails again consult a competent electrician.
3.1.2 Power cut. Check other appliances and if
necessary, contact local Electricity Supply Co.
3.2.1 Consult a competent electrician or contact
Customer Service.
3.3.1 Thermal protection on motor has
operated. Allow appliance to cool and reset
itself. If it persists, contact Customer Service.
3.4.1 Remove cover and connect start/stop
switch.