Fault Finding - Triton EDEN Bar Diverter Manual

Thermostatic bar diverter
Table of Contents

Advertisement

The following can be carried out by a competent person
Problem
1 Water too hot.
2 Water too cold.
Thermostatic bar mixer shower

FAULT FINDING

Cause
1.1 Temperature
control incorrectly
commissioned.
1.2 Not enough cold
water flowing through
shower.
1.3 Increase in the
ambient cold water
temperature.
1.4 Cold water supply
blocked.
1.5 High volume of cold
water drawn off
elsewhere.
2.1 Temperature control
incorrectly
commissioned.
2.2 Not enough hot water
flowing through
shower.
2.3 Decrease in the
ambient cold water
temperature.
2.4 Insufficient hot water
supplies from the
heating system.
2.5 Hot water supply
blocked or restricted.
Action
1.1.1 Refer to the Commissioning section.
1.2.1 Reposition temperature control knob
1.3.1 Reposition temperature control knob.
1.4.1 Turn off the shower and consult a
competent plumber or contact
Customer Experience.
1.5.1 Reduce the simultaneous demand from
the supply.
2.1.1 Refer to the Commissioning section.
2.2.1 Reposition temperature control knob
2.3.1 Reposition temperature control knob
2.4.1 Make sure heating appliance is set to
maximum or has sufficient stored hot water.
2.4.2 Make sure heating appliance is igniting by
trying a hot water tap elsewhere.
2.5.1 Turn off shower and consult a competent
plumber or contact Customer Experience.
15