YASKAWA DX200 Operator's Manual page 69

Hide thumbs Also See for DX200:
Table of Contents

Advertisement

169861-1CD
Weldcom Function: Arc
Welding Digital I/F
Alarm
Alarm
No.
Name
4271
MOTOWELD
VOLT.DETEC
T WIRE
ERROR
4272
MOTOWELD
SAFTY-
CIRCUIT
ERROR
4273
MOTOWELD
IGBT SHORT
CIRCUIT
4274
MOTOWELD
VOLTAGE
DETECTOR
ERROR
4275
MOTOWELD
AUX.
CIRCUIT OV.
CURRENT
4276
MOTOWELD
DSP ADC
ERROR
5
Alarm and Error
5.1 Alarm
Sub
Meaning
Code
702
Sub Code: MOTOWELD's Err Code.
101
Sub Code: MOTOWELD's Err Code.
104
Sub Code: MOTOWELD's Err Code.
110
Sub Code: MOTOWELD's Err Code.
111
Sub Code: MOTOWELD's Err Code.
119
Sub Code: MOTOWELD's Err Code.
Remedy
(1)Check if the voltage detection wire
is connected. Check to confirm that
the welding voltage sensing cable
select switch is set to "Base Metal".
The use of MOTOWELD-RP500:
Check to confirm that the voltage
sensing cable is connected between
the base metal and the terminal
block TB2 7.
The use of MOTOWELD-RL350/
X350:
Check to confirm that the base
metal-side welding voltage sensing
cable connects between the base
metal and the welding power source
via wire feeder cable.
(2)Check to confirm that the contact
chip and the welding work are not in
contact. Cancel the contact if any,
and weld them.
(3)Temporary power failure may
have occurred.
(4) When the welding voltage
sensing cable is used, please
connect the welding voltage sensing
cable to the base metal.
(5) When the AC unit used, a
weldingpower source output cable,
please?confirm whether the output
cable of the wiring of the AC unit is
not a mistake.
(6) When the AC unit used, please
make sure that the power of the AC
unit is turned on.
Contact your YASKAWA
representative.
Replace the IGBT device (Part code
AJ0EL3870). Contact your
YASKAWA representative.
Contact your YASKAWA
representative.
The board may be broken. Contact
your YASKAWA representative.
Contact your YASKAWA
representative.
HW1482771
5-19
69 of 75

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents