YASKAWA DX200 Operator's Manual page 54

Hide thumbs Also See for DX200:
Table of Contents

Advertisement

Weldcom Function: Arc
Welding Digital I/F
Alarm
Alarm
No.
Name
TPS:
4290
ERROR
5
Alarm and Error
5.1 Alarm
Sub
Meaning
Code
26
Err26.x
Sub code[26**] shows the error code of
Fronius power source
26 :main error code
** :sub error code
27
Err027
Sub code[27**] shows the error code of
Fronius power source
27 :main error code
** :sub error code
28
Err028
Sub code[28**] shows the error code of
Fronius power source
28 :main error code
** :sub error code
29
DSPC
Sub code[29**] shows the error code of
Fronius power source
29 :main error code
** :sub error code
30
EFd
Sub code[30**] shows the error code of
Fronius power source
30 :main error code
** :sub error code
31
Err31
Sub code[31**] shows the error code of
Fronius power source
31 :main error code
** :sub error code
32
EcF
Sub code[32**] shows the error code of
Fronius power source
32 :main error code
** :sub error code
33
tSt
Sub code[33**] shows the error code of
Fronius power source
33 :main error code
** :sub error code
Remedy
Check whether the CfgMem has
good contact to the connecting
cables and in the plug.
Re-crimp if necessary.
If this does not help, remove and
send to Fronius Austria, together
with details of the series number of
the machine.
Confirm the Fronius's manual
Measure the +24VDC of NT 24
Confirm the Fronius's manual
Change the cooling-unit temperature
sensor
Confirm the Fronius's manual
Update firmware, otherwise change
the UST board
Confirm the Fronius's manual
Check wire feed system.
Confirm the Fronius's manual
Update firmware, otherwise change
the UST board
Confirm the Fronius's manual
Install correct primary BPS power
module
Confirm the Fronius's manual
Allow the machine to cool
Confirm the Fronius's manual
5-4