Outdoor Unit

2.2.4 Removal of the PCB

Procedure
Step
Remove the electrical box.
1. Remove the PCB.
Disconnect the
1
connectors for the
control PCB (S52,
S102).
Undo the 4 clamps by
2
pliers.
Loosen the fixing screw
3
of the cable way board
and disconnect the
earth wire.
206
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.