Removal Of Fan Motor - Daikin ATXS35EV1B7 Service Manual

Inverter pair e-series
Hide thumbs Also See for ATXS35EV1B7:
Table of Contents

Advertisement

SiBE04-824
1.8
Removal of
Procedure
Step
Undo the fan motor
1
lead wires from the
hooks.
2
Loosen and remove the
fan rotor lock screw.
Remove the 2 screws
3
of the fan motor fixing
plate.
Removal Procedure
Fan Motor
Warning
Be sure to turn off all power supplies at least 10 min. before
disassembling work.
Procedure
Indoor Unit
Points
Preparation
Remove the drain pan unit
according to the "Removal
of Drain Pan Unit."
You can remove the fan
motor with the heat
exchanger left.
It is easy to clean up the
heat exchanger.