Indoor Unit

1. Indoor Unit

1.1
Removal of
Procedure
Step
1. Appearance feature
2. Removing the air filter
1
Put your fingers on the
right and left projections
of the front panel, and
open the panel to the
position where it will
stop.
Slightly push up the
2
knob at the center of
the air filter and release
the hook.
3
Pull out the air filter
downwards and remove
it.
138
Air Filter
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Signal receiver
ON/OFF switch
Room temperature
(Test run switch)
thermistor
Dangerous: High voltage
A high voltage is applied to
all the electric circuits of this
product including
thermistors.
The panel designs are
different according to the
models.
(R4305)
When a signal from the
Operation lamp
remote controller is
TIMER lamp
received, the receiving tone
INTELLIGENT EYE
lamp
sounds and the operation
lamp flickers immediately to
confirm the signal reception.
When the ON/OFF switch is
kept pressed for 5 seconds,
the forced cooling operation
INTELLIGENT EYE
is performed for about 15
(R4306)
minutes.
(R4307)
The air filter is not marked
for difference between the
right and left sides.
The air filter can be set
easily by inserting it along
the guides.
Insert the air filter with the
"FRONT"-marked face up.
Be sure to insert the hooks
(at 2 lower positions) when
mounting the air filter.
(R4308)
SiBE04-824
Points
Warning
Removal Procedure