DSC HS2016 Reference Manual page 90

Powerseries neo control panels
Hide thumbs Also See for HS2016:
Table of Contents

Advertisement

Section 5: Programming
3 – RF Jam Trouble Beeps
ON: Trouble beeps sound when an RF Jam Trouble is detected
OFF: Trouble beeps do not sound when an RF Jam Trouble is detected
4 – Multi Hit
ON: Alarms from the same zone within the Burglary Verification Timer duration cause the police code or burglary verified to
be logged and transmitted. The number of zone trips required to create a confirmed alarm depends on the value of the pro-
grammable burglary verification counter.
OFF: Alarms from the same zone within the Burglary Verification Timer duration do not cause the police code or burglary veri-
fied to be logged and transmitted.
Note: This feature only applies to zones defined as Interior, Interior Delay, Interior Stay/Away, Instant Stay/Away, Delay
Stay/Away, or Night Zones (PIR Zones). Do enable this option if section [380], option 2 - Restore on Bell Time Out is
enabled.
5 – Late to Close
ON: Provides an audible warning if the alarm system has not been armed by a programmed time of day but does not arm the
alarm system. The alarm system communicates and logs a Late to Close event at the end of the Auto-arm/Postpone pre-alert
for each partition.
OFF: The alarm system will neither communicate nor log a Late to Close event at the time programmed for Auto-arm for each
partition.
Note: If the Auto-arm toggle option is disabled, the Auto-arm Pre-alert still occurs when a time is programmed for that day (if
enabled) and the event is logged and communicated. This option does not directly affect the functionality of Auto-arm. If Late
to Close is enabled and Auto-arming is not, LCD keypads display "System Arming in Progress" during the Late to Close Pre-
alert.
6 – Daylight Savings Time
ON: The alarm system adjusts between Daylight and Standard times according to the times programmed in System Timers
([005] options 001-002).
Note: Auto-arm and Test Transmissions should not be attempted between 0200 and 0300 hours, as they will be missed dur-
ing a daylight savings clock adjust. Events programmed to occur between 0100 and 0200 will occur twice during a daylight
savings clock adjust. Daylight Savings Time programming should not conflict with the Auto-arm and Test Transmissions pro-
gramming.
OFF: The alarm system makes no automatic time adjustments for Daylight Saving time.
7 – Silence Chime During Quick Exit Delay
ON: Door chime does not sound during quick exit.
OFF: Door chime sounds during quick exit, according to zone settings.
8 – Bell Squawk on Away Arm/ Disarm Only
ON: Bell Squawks are only heard when away arming, as well as when disarming from Away mode. This feature prevents the
siren from activating when arming in stay and night modes.
OFF: Bell Squawks are heard during all types of arming and disarming.
Note: This option follows the "Bell Squawk Attribute" features if they are enabled.
[018] System Option 6
1 – Test Transmission Exception
ON: The alarm system does not send a test transmission if a transmission was sent to the receiver within the programmed
interval as set in section [377]>See "[003] – Periodic Test Transmission Cycle" on page 109.
OFF: Test transmissions are always sent at the programmed interval.
2 – Real-Time Bypass Reporting
ON: When a non-24-hour zone is bypassed in [*][1], the system immediately logs and communicates the bypass status of the
zone.
Global Zones: 24-hour and non-24 hour zone bypasses are logged and communicated in real time. Non-24 hour zone unby-
pass events are generated when the last assigned partition is disarmed.
- 90 -