[07] System Test
[09] Night Arm
[12] Global Stay Arm
[13] Global Away Arm
[14] Global Disarming
[16] Quick Exit
To program a function key:
1. Enter Installer Programming [*][8].
2. Enter section [861] for keypad 1 function key programming.
3. Enter [001] to [005] to select a function key to program.
4. Enter a 2-digit number to assign a function key operation - [00] - [68]. See table above.
5. Continue from step 3 until all function keys are programmed.
6. Press the [#] key twice to exit Installer Programming.
Programmed function keys must be pressed for 2 seconds in order to activate the function.
4.5.1 Function Key Definitions
This section provides detailed descriptions of each programmable function key option.
[00] Null Function Key
This option deactivates the function key. The key does not perform any function when pressed.
[02] Instant Stay Arm
This feature is similar to the Stay Arm function key, except that no exit delay is applied and the system arms immediately.
If no Stay/Away zone types are programmed, the alarm system arms in Away mode.
Note: Do not use this function with CP-01 installations.
[03] Stay Arm
Only perimeter zones are armed. Interior zones are bypassed regardless of whether or not delay zones are tripped during
the exit delay.
[04] Away Arm
All interior and perimeter zones are armed. CP-01 panels require an exit through a delay zone during the exit delay or the
system will arm the perimeter zones only.
[05] No-Entry Arm [*][9]
All Delay 1 and Delay 2 zones become instant zones. If a door or window is opened the system goes immediately into alarm.
This function is typically used when no occupants are expected to return to the site during the armed period. Activation of this
function key requires an access code. This function only works while the system is disarmed.
See "[*][9] No-Entry Arming" on page 53 for more information.
[06] Chime On/Off
This function turns the door chime on or off and is the equivalent of pressing [*][4]. The alarm system must be disarmed to
use this function. If option 7 in section [023] is enabled, this function key requires an access code.
[07] System Test
This function performs a system test when pressed and is the equivalent of entering [*][6][Access Code][04]. The alarm sys-
tem must be disarmed to use this function. See "[*][6] User Functions" on page 50 for more information.
[09] Night Arm
All perimeter and interior zones, excluding Night zones, are armed. This key only works while the system is disarmed or
armed in Stay mode.
If no Night type zones are programmed, the alarm system arms in Away mode with an audible exit delay. Exit delay is silent.
Arming in this mode activates the Away Arming PGM output.
Section 4: System Operation
[34] User Programming [*][5]
[35] User Functions [*][6]
[37] Time & Date Program
[39] Trouble Display [*][2]
[40] Alarm Memory [*][3]
[61]-[68] Partition 1 to 8 Select
- 38 -