DSC HS2016 Reference Manual page 202

Powerseries neo control panels
Hide thumbs Also See for HS2016:
Table of Contents

Advertisement

Aux Power Supply Trouble
TLM Trouble
General System Tamper
General System Supervisory
Openings & Closings - Sets Residential Dial Reporting Codes for all openings and closings
l
Openings/Closings Group
Enable All User Open/Close Reports
Zone Alarm Restore Group - Disables all zone alarm restore reporting codes
l
Zone Alarm Restore Group
Restore zone alarm reporting codes
Installer Lead-in/Lead-out and DLS Lead-in/Lead-out
l
DLS/Installer Lead In/Out Group
DLS/Installer Disabled
Digit 5 DLS Connection Options
Option
Programming Section
[401] Option 1 OFF
Option 3 OFF
1
Option 4 OFF
[406] 000
Appendix 3: Template Programming Tables
[308][302] - Bit 5 Panel AUX Trouble - On
[308][302] - Bit 6 Panel AUX Trouble Restore - On
[308][332] - Bit 5 Module AUX Trouble - On
[308][332] - Bit 6 Module AUX Trouble Restore - On
[308][302] - Bit 3 Panel TLM Trouble - Off
[308][302] - Bit 4 Panel TLM Trouble Restore - On
[308][101] - Bit 3 Module Tamper Trouble - Off
[308][101] - Bit 4 Module Tamper Restore - Off
[308][332] - Bit 3 Module Supervisory Trouble - On
[308][332] - Bit 4 Module Supervisory Restore - On
Openings/Closings Programming
[308][201] - Bit 1 User Closing - On
[308][201] - Bit 2 User Opening - On
[308][201] - Bit 5 Special Closing - On
[308][201] - Bit 6 Special Opening - On
[308][202] - Bit 1 Automatic Closing - On
[308][202] - Bit 2 Automatic Opening - On
[308][202] - Bit 3 Automatic Cancel - On
DLS/Installer Lead In/Out Programming
[307][001] - Bit 2 Alarm Restore - Off
[307][002] - Bit 2 Alarm Restore - Off
[307][003] - Bit 2 Alarm Restore - Off
[307][004] - Bit 2 Alarm Restore - Off
[307][005] - Bit 2 Alarm Restore - Off
[307][006] - Bit 2 Alarm Restore - Off
[307][007] - Bit 2 Alarm Restore - Off
[307][008] - Bit 2 Alarm Restore - Off
[307][009] - [128] Bit 2 Alarm Restore - Off
DLS/Installer Lead In/Out Programming
[308][312] - Bit 1 Installer Lead In - Off
[308][312] - Bit 2 Installer Lead Out - Off
[308][312] - Bit 3 DLS Lead In - Off
[308][312] - Bit 4 DLS Lead Out - Off
[308][312] - Bit 5 SA Lead In - Off
[308][312] - Bit 6 SA Lead Out - Off
DLS Connection/Call Back Setting
Double Call Disabled
Call Back Disabled
User Initiated Call Up Disabled
Number of Rings to Answer On Disabled
- 202 -