DSC HS2016 Reference Manual page 203

Powerseries neo control panels
Hide thumbs Also See for HS2016:
Table of Contents

Advertisement

[401] Option 1 ON
Option 3 OFF
2
Option 4 OFF
[406] 008
[401] Option 1 ON
Option 3 ON
3
Option 4 OFF
[406] 008
[401] Option 1 ON
Option 3 OFF
4
Option 4 ON
[406] 008
After entering a valid 5-digit template programming code, the system prompts for the following data in the sequence listed:
1. Central Station Telephone Number
i. Program the required central station phone number. Press [#] to complete your entry.
ii. This phone number is entered into programming section [301][001].
2. Central Station System Account Code (4 or 6-digit code)
i. Program the system account code. All digits must be entered in order to complete your entry.
ii. This account code is entered into programming section [310][000].
3. Partition 1 Account Code (4 digit code)
i. Program the partition 1 account code. All digits must be entered in order to complete your entry.
ii. This account code is entered into programming section [310][001]
4. DLS Access Code (6-digit code)
i. Program the required DLS access code. All 6 digits must be entered in order to complete your entry.
ii. This access code is entered into programming section [403].
5. Entry Delay 1 and Exit Delay
i. Enter the 3-digit entry delay 1 (in seconds) followed by the desired 3-digit exit delay (in seconds). These entries affect
all partitions.
ii. All 3 digits must be entered in order to complete each section entry.
iii. These values are entered in programming sections [005][001]-[008] entry 1 and 3 respectively.
6. Installer's Code
i. Enter the 4, 6 or 8-digit installer access code (dependent on section [041]). All digits must be entered in order to com-
plete the section entry.
ii. This code is entered into programming section [006][001].
iii. After the installer code has been programmed the system returns to the base installer programming menu.
iv. All template programming information defaults after performing a hardware or software panel default. The 5-digit tem-
plate programming code is defaulted to 0000000.
Note: Pressing the pound key (#) advances through template programming, accepting what is displayed in these locations,
potentially overwriting desired programming. Depending on the option programmed, restoring the defaults using template
programming may not be possible.
Appendix 3: Template Programming Tables
Double Call Enabled
Call Back Disabled
User Initiated Call Up Disabled
Number of Rings to Answer On is 8
Double Call Enabled
Call Back Enabled
User Initiated Call Up Disabled
Number of Rings to Answer On is 8
Double Call Enabled
Call Back Disabled
User Initiated Call Up Enabled
Number of Rings to Answer On is 8