Configure Switch B
3.
# Create dynamic aggregate interface 2.
<SwitchB> system-view
[SwitchB] interface bridge-aggregation 2
[SwitchB-Bridge-Aggregation2] link-aggregation mode dynamic
[SwitchB-Bridge-Aggregation2] quit
#Add ports GigabitEthernet 1/0/1, GigabitEthernet 1/0/2, and GigabitEthernet 1/0/3 that connect to
IRF member switches to aggregation group 2 (corresponding to aggregate interface 2).
[SwitchB] interface GigabitEthernet 1/0/1
[SwitchB-GigabitEthernet1/0/1] port link-aggregation group 2
[SwitchB-GigabitEthernet1/0/1] quit
[SwitchB] interface GigabitEthernet 1/0/2
[SwitchB-GigabitEthernet1/0/2] port link-aggregation group 2
[SwitchB-GigabitEthernet1/0/2] quit
[SwitchB] interface GigabitEthernet 1/0/3
[SwitchB-GigabitEthernet1/0/3] port link-aggregation group 2
[SwitchB-GigabitEthernet1/0/3] quit
Configure Switch C
4.
# Create dynamic aggregate interface 3.
<SwitchC> system-view
[SwitchC] interface bridge-aggregation 3
[SwitchC-Bridge-Aggregation3] link-aggregation mode dynamic
[SwitchB-Bridge-Aggregation3] quit
# Add ports GigabitEthernet 1/0/1, GigabitEthernet 1/0/2, and GigabitEthernet 1/0/3 that connect
to IRF member switches to aggregation group 3 (corresponding to aggregate interface 3).
[SwitchC] interface GigabitEthernet 1/0/1
[SwitchC-GigabitEthernet1/0/1] port link-aggregation group 3
[SwitchC-GigabitEthernet1/0/1] quit
[SwitchC] interface GigabitEthernet 1/0/2
[SwitchC-GigabitEthernet1/0/2] port link-aggregation group 3
[SwitchC-GigabitEthernet1/0/2] quit
[SwitchC] interface GigabitEthernet 1/0/3
[SwitchC-GigabitEthernet1/0/3] port link-aggregation group 3
[SwitchC-GigabitEthernet1/0/3] quit
Configuring the TFTP server
Obtain the new system software image through a legal channel, and save the file to the working
directory of the TFTP server so that the TFTP client can access the file. The working directory varies with
TFTP server models.

ISSU upgrade preparation

Download the new system software image soft-version2.bin
# Download system software image soft-version2.bin to the root directory of the Flash of each IRF
member switch.
<IRF> tftp 2.2.2.2 get soft-version2.bin
File will be transferred in binary mode